Back to AD

AD 71-20-03 ACTIVE

Relay In Elevator Servodyne Circuit
Key Information
AD Number 71-20-03 Status Active
Effective Date October 18, 1971 Issue Date Not specified
Docket Number Unknown Amendment 39-1296
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Sud Aviation
Model(s) Caravelle SE 210 Model VIR
Regulatory Text

71-20-03 SUD AVIATION: Amendment 39-1296. Applies to Sud Model SE.210, MK VI-R, "Caravelle" airplanes.

Within the next 500 hours' time in service after the effective date of this AD, unless already accomplished, incorporate S.A. Modification 1592 by installing a holding relay in the elevator servodyne jamming warning circuit in accordance with Sud Service-Caravelle Bulletin No. 27-218 at Revision 4, dated March 27, 1970, or an FAA-approved equivalent.

This amendment becomes effective October 18, 1971.