Back to AD

AD 67-01-02 ACTIVE

Rotor Discs
Key Information
AD Number 67-01-02 Status Active
Effective Date August 24, 1976 Issue Date August 02, 1976
Docket Number Unknown Amendment 39-2688
Product Type ["Engine"] Product Subtype Not specified
CFR Part --- - Part 39 CFR Section --- - _EMPTY_
Citation This information is not available.
Applicability
Manufacturer(s) General Electric Company
Model(s) CT58-100-1 T58-GE-5 T58-GE-1 CT58-100-2 CT58-110-1 CT58-110-2 CT58-140-1 CT58-140-2
Regulatory Text

67-01-02 GENERAL ELECTRIC: Amendment 39-332 as amended by Amendment 39-536 and Amendment 39-1085 is further amended by Amendment 39-2688. Applies to Model CT58-100-1, CT58-100-2, CT58-110-1, CT58-110-2, CT58-140-1, CT58-140-2, T58-GE-1 and T58-GE-5 Engines.

Compliance required as indicated.

To ensure adequate life limit margin for first stage compressor rotor discs, remove from service G.E. P/N's 37D400218P101, 37D400218P101 CEB #148, 37D400218P102, 37D400359P101, 37D400359P102, 3920T11P01, 3920T11P02, 5013T06P01, 5001T20P01, and 5001T20P02 as follows:

(a) Discs with more than 9,700 cycles on October 15, 1970, prior to the accumulation of 200 additional cycles.

(b) Discs with 9,700 cycles or less on October 15, 1970, before 9,900 cycles.

For the purposes of this AD a cycle is considered as any engine operating sequence involving engine start, at least one acceleration to a power required for take off, and shutdown.

Amendment 39-332 became effective December 29, 1966.

Amendment 39-536 became effective January 9, 1968.

Amendment 39-1085 became effective October 15, 1970.

This amendment 39-2688 becomes effective August 24, 1976.

Office of Primary Responsibility
["AIR-720: Operational Safety Branch"]