Back to AD

AD 69-19-02 ACTIVE

Cable Lugs
Key Information
AD Number 69-19-02 Status Active
Effective Date September 20, 1969 Issue Date Not specified
Docket Number Unknown Amendment 39-823
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Vickers-Armstrongs (Aircraft Limited)
Model(s) Viscount 744 Viscount 745D
Regulatory Text

69-19-02 VICKERS: Amdt. 39-823. Applies to Viscount Models 744 and 745D Series Airplanes equipped with aluminum heavy duty cable lugs connected to the engine starter selector relay.

Compliance: Required within the next 1,500 hours' time in service after the effective date of this AD, unless already accomplished.

To prevent the overheating of the aluminum heavy duty cable lugs during engine starting replace the existing engine starting selector relay locking nut, bolt, and washers with a captive locking nut P/N 80236 Sht. 893, revised securing bolt P/N 72436-2749 and washers 74736-287, in accordance with British Aircraft Corp. Viscount Modification Bulletin No. D.3219 Issue 1, dated September 9, 1968, or later ARB-approved issue or an FAA-approved equivalent. The aluminum cable lug connections to engine starter selector relays are located in the main landing gear wheel bay at Nose Rib Station 131, LH and RH wings.

This amendment becomes effective September 20, 1969.