Back to AD

AD 67-25-07 ACTIVE

Heat Detectors
Key Information
AD Number 67-25-07 Status Active
Effective Date September 07, 1967 Issue Date Not specified
Docket Number Unknown Amendment 39-473
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Vickers-Armstrongs (Aircraft Limited)
Model(s) Viscount 744 Viscount 745D Viscount 810
Regulatory Text

67-25-07 VICKERS: Amdt. No. 39-473, Part 39, Federal Register September 7, 1967. Applies to Viscount Models 744, 745D and 810 Series Airplanes.

Within the next 1,000 hours' time in service after the effective date of this AD, unless already accomplished:

Replace Graviner D.1870 or D.1870N/1 loop type overheat detectors with Graviner D.5352N/1 coil overheat detectors. Replace Graviner point type detectors as shown in the following table:

Existing P/N
Replacement P/N
Graviner 4D/3
Graviner 134D/3
Graviner 13D/3
Graviner 135D/3
Graviner 68D/3
Graviner 136D/3
Graviner 150D/07/180
Graviner 150D/07/210

Detectors which are equivalent to the specified Graviner detectors may be used as replacements, subject to the approval of the Chief, Aircraft Certification Staff, FAA, Europe, Africa, and Middle East Region.

Replace the detectors in accordance with British Aircraft Corporation Limited (BAC) Modification Bulletin No. D.3187, Issue 2, (700 Series), and Modification Bulletin No. FG.2055, Issue 2, (810 Series), or an equivalent approved by the Chief, Aircraft Certification Staff, FAA, Europe, Africa, and Middle East Region.

This amendment effective September 7, 1967.