Back to AD

AD 81-05-03 ACTIVE

Fuel tank shut-off valve modification
Key Information
AD Number 81-05-03 Status Active
Effective Date March 11, 1981 Issue Date Not specified
Docket Number Unknown Amendment 39-4053
Product Type ["Aircraft"] Product Subtype ["Balloon"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) JR Aerosports, LTD
Model(s) Firefly 5 Firefly 6 Firefly 6B Firefly 7 Firefly 7B Firefly 8-24
Regulatory Text

81-05-03 THE BALLOON WORKS: Amendment 39-4053. Applies to Firefly Models 5, 6, 6B, 7, 7B and 8-24 series hot air balloons equipped with Fire 2 auxiliary heaters incorporating The Balloon Works fuel tanks part numbers BW 3229-A through BW 3229-N and BW 3307-A through BW 3307-H, certificated in all categories.

Compliance required within the next 10 hours time in service after the effective date of this AD, unless already accomplished.

To prevent inadvertent operation of the Fire 2 heater system during a hard landing, even though the tank valve has been closed, accomplish the following:

Modify the Fire 2 fuel tank shut-off valve in accordance with The Balloon Works Service Bulletin B12 dated December 15, 1980, or later FAA approved revision, or an equivalent method approved by the Chief, Engineering and Manufacturing Branch, Southern Region.

Make an appropriate maintenance record showing compliance with this AD.

This amendment becomes effective March 11, 1981.