Back to AD

AD 73-12-10 ACTIVE

Dc Power Control Box
Key Information
AD Number 73-12-10 Status Active
Effective Date July 06, 1973 Issue Date Not specified
Docket Number Unknown Amendment 39-1660
Product Type ["Aircraft"] Product Subtype ["Small/Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) British Aerospace Regional Aircraft
Model(s) H.P. 137 Jetstream Mk. 1
Regulatory Text

73-12-10 HANDLEY PAGE (JETSTREAM AIRCRAFT LTD): Amdt. 39-1660. Applies to Model HP-137 Mk 1 airplanes.

Compliance is required within the next 50 hours' time in service after the effective date of this AD unless already accomplished.

To prevent the possible unnecessary interruption of current flow to the battery bus and non-essential bus, replace the 30 amp fuse, F10 in the D.C. power control box with a 25 amp Klixon circuit breaker, P/N D6761- 1-25, in accordance with Jetstream Aircraft Limited Modification No. 5006, Parts 1 and 2, dated September 1971, or an FAA-approved equivalent.

This amendment becomes effective July 6, 1973.