AD 98-06-17 ACTIVE

Water Heater Control Relays
Key Information
AD Number 98-06-17 Status Active
Effective Date April 20, 1998 Issue Date Not specified
Docket Number 97-NM-193-AD Amendment 39-10395
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 [63 FR 12613 NO. 50 03/16/98] CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Dassault Aviation
Model(s) Mystere-Falcon 900
Summary

This amendment adopts a new airworthiness directive (AD), applicable to certain Dassault Aviation Model Mystere Falcon 900 series airplanes, that requires replacement of the water heater control relays with improved relays having high-power contactors; the addition of a testing and monitoring circuit for each contactor; and installation of improved electrical bonding of the potable water tank. This amendment is prompted by issuance of mandatory continuing airworthiness information by a foreign civil airworthiness authority. The actions specified by this AD are intended to prevent overheating of the water heaters for the galley or the washbasin, which could result in damage to the water heater and nearby electrical wiring, and consequent smoke in the cabin.

Action Required

Final rule

Regulatory Text

98-06-17 DASSAULT AVIATION: Amendment 39-10395. Docket 97-NM-193-AD.
Applicability: Model Mystere Falcon 900 airplanes; equipped with l'HOTELLIER water system gauges having part number (P/N) 5250, 5251, 5250-1 or 5251-1; certificated in any category.

NOTE 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.Compliance: Required as indicated, unless accomplished previously.

To prevent overheating of the water heaters for the galley or the washbasin, which could result in damage to the water heater and nearby electrical wiring, and consequent smoke in the cabin, accomplish the following:

(a) Within 7 months or 330 flight hours after the effective date of this AD, whichever occurs first: Replace the water heater control relays with improved relays; add a testing and monitoring circuit for each contactor; and install improved electrical bonding of the potable water tank; in accordance with Dassault Service Bulletin F900-181 (F900-38-12), dated December 4, 1996.

(b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, International Branch, ANM-116, FAA, Transport Airplane Directorate. Operators shall submit their requests through an appropriate FAA Principal MaintenanceInspector, who may add comments and then send it to the Manager, International Branch, ANM-116.

NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the International Branch, ANM-116.

(c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.

(d) The actions shall be done in accordance with Dassault Service Bulletin F900-181 (F900-38-12), dated December 4, 1996. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Dassault Falcon Jet Corporation, Teterboro Airport, P.O. Box 2000, South Hackensack, New Jersey 07606. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.

NOTE 3: The subject of this AD is addressed in French airworthiness directive 96-279-018(B), dated December 4, 1996.

(e) This amendment becomes effective on April 20, 1998.

Supplementary Information

A proposal to amend part 39 of the Federal Aviation Regulations (14 CFR part 39) to include an airworthiness directive (AD) that is applicable to certain Dassault Aviation Model Mystere Falcon 900 series airplanes was published in the Federal Register on January 5, 1998 (63 FR 171). That action proposed to require replacement of the water heater control relays with improved relays having high-power contactors; the addition of a testing and monitoring circuit for each contactor; and installation of improved electrical bonding of the potable water tank.

Comments
Interested persons have been afforded an opportunity to participate in the making of this amendment. No comments were submitted in response to the proposal or the FAA's determination of the cost to the public.

Conclusion
The FAA has determined that air safety and the public interest require the adoption of the rule as proposed.

Cost Impact
The FAA estimates that 1 airplane of U.S. registry will be affected by this AD, that it will take approximately 24 work hours per airplane to accomplish the required actions, and that the average labor rate is $60 per work hour. Required parts will cost approximately $6,300 per airplane. Based on these figures, the cost impact of the AD on the single U.S. operator is estimated to be $7,740.

The cost impact figure discussed above is based on assumptions that no operator has yet accomplished any of the requirements of this AD action, and that no operator would accomplish those actions in the future if this AD were not adopted.

Regulatory Impact
The regulations adopted herein will not have substantial direct effects on the States, on the relationship between the national government and the States, or on the distribution of power and responsibilities among the various levels of government. Therefore, in accordance with Executive Order 12612, it is determined that this final rule does not have sufficient federalism implications to warrant the preparation of a Federalism Assessment.

For the reasons discussed above, I certify that this action (1) is not a significant regulatory action under Executive Order 12866; (2) is not a significant rule under DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979); and (3) will not have a significant economic impact, positive or negative, on a substantial number of small entities under the criteria of the Regulatory Flexibility Act. A final evaluation has been prepared for this action and it is contained in the Rules Docket. A copy of it may be obtained from the Rules Docket at the location provided under the caption ADDRESSES.

List of Subjects in 14 CFR Part 39
Air transportation, Aircraft, Aviation safety, Incorporation by reference, Safety.

Adoption of the Amendment
Accordingly, pursuant to the authority delegated to me by the Administrator, the Federal Aviation Administration amends part 39 of the Federal Aviation Regulations (14CFR part 39) as follows:

PART 39 - AIRWORTHINESS DIRECTIVES
1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.

39.13 [Amended]
2. Section 39.13 is amended by adding the following new airworthiness directive:

Addresses

The service information referenced in this AD may be obtained from Dassault Falcon Jet Corporation, Teterboro Airport, P.O. Box 2000, South Hackensack, New Jersey 07606. This information may be examined at the Federal Aviation Administration (FAA), Transport Airplane Directorate, Rules Docket, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.

For Further Information Contact

Norman B. Martenson, Manager, International Branch, ANM-116, FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington 98055-4056; telephone (425) 227-2110; fax (425) 227-1149.