92-27-11 R1 MCDONNELL DOUGLAS: Amendment 39-8491. Docket 93-NM-07-AD. Revises AD 92-27-11, Amendment 39-8446. \n\n\tApplicability: McDonnell Douglas Model MD-11 and MD-11F series airplanes; as listed in McDonnell Douglas MD-11 Alert Service Bulletin A76-3, dated November 17, 1992; certificated in any category. \n\n\tCompliance: Required as indicated, unless accomplished previously. \n\n\tTo prevent inhibited operation of the engine emergency fire extinguisher system, accomplish the following: \n\n\t(a)\tWithin 30 days after the effective date of this AD, perform a functional inspection for proper actuation of the fire bottle switch, and a visual inspection of the fire shutoff handle cover assembly to verify whether a minimum clearance of 0.030 inch (0.76 mm) exists between the fire shutoff handles, cover assembly, and rub strips in the flight compartment, in accordance with the Accomplishment Instructions of McDonnell Douglas MD-11 Alert Service Bulletin A76-3, dated November 17, 1992. \n\n\t\t(1)\tIf any fire bottle switch actuates (audible click), and if any handle clearance is found to be 0.030 inch (0.76 mm) or greater, no further action is necessary; or \n\n\t\t(2)\tIf any fire bottle switch does not actuate (click is not audible), and/or any handle clearance is not found to be 0.030 inch (0.76 mm) or greater, prior to further flight, trim the cover assembly handle cutout and rub strips to achieve a clearance of 0.030 inch (0.76 mm) or greater, and repeat the functional inspection requirements for proper switch actuation in accordance with paragraph (a) of this AD. \n\n\t(b)\tAn alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Los Angeles Aircraft Certification Office (ACO), FAA, Transport Airplane Directorate. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, LosAngeles ACO. \n\n\tNOTE: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Manager, Los Angeles ACO. \n\n\t(c)\tSpecial flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished. \n\n\t(d)\tThe functional inspection and trim shall be done in accordance with McDonnell Douglas MD-11 Alert Service Bulletin A76-3, dated November 17, 1992. This incorporation by reference was approved previously by the Director of the Federal Register, in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51, as of January 13, 1993 (57 FR 61791, December 29, 1992). Copies may be obtained from McDonnell Douglas Corporation, P.O. Box 1771, Long Beach, California 90846-1771, Attention: Business Unit Manager, Technical Publications - Technical Administrative Support, C1-L5B. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at FAA, Transport Airplane Directorate, Los Angeles Aircraft Certification Office, 3229 East Spring Street, Long Beach, California; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. \n\n\t(e)\tThis amendment becomes effective on February 8, 1993.