Back to AD

AD 54-02-01 ACTIVE

Magneto Timing
Key Information
AD Number 54-02-01 Status Active
Effective Date Not specified Issue Date Not specified
Docket Number Unknown Amendment N/A
Product Type ["Engine"] Product Subtype Not specified
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Textron Lycoming, AVCO Corporation
Model(s) O-290-D2
Regulatory Text

54-02-01 LYCOMING: Applies to All Model O-290-D2 Engines.
Compliance required by February 1, 1954, and at each subsequent 100-hour inspection.
In order to preclude the possibility of serious engine damage from incipient detonation under certain atmospheric and altitude conditions, the magneto timing of all Lycoming O-290-D2 engines must be set at 18 degrees BTC. To insure that the magneto timing does not change substantially from this setting, it should be checked and reset, if necessary, at each subsequent 100-hour inspection.
(Lycoming Service Bulletin No. 169 covers this same subject, but recommends that the timing be checked every 50 hours.)