Back to AD

AD 47-30-07 ACTIVE

Trip-Free Circuit Breaker
Key Information
AD Number 47-30-07 Status Active
Effective Date Not specified Issue Date Not specified
Docket Number Unknown Amendment N/A
Product Type ["Aircraft"] Product Subtype ["Small Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Textron Aviation Inc.
Model(s) Army AT-11
Regulatory Text

47-30-07 BEECH: (Was Mandatory Note 3 of AD-2-582-2.) Applies Only to AT-11 Aircraft Which Are Not Equipped With Generator Circuit Protective Devices.

To be accomplished prior to certification or, if certificated, on next periodic inspection but not later than October 1, 1947.

In accordance with Figure 1 install a 50-ampere trip-free circuit breaker, Spencer Thermostat Co. PLM-50 or equivalent, between the battery terminal of each generator cutout and its respective ammeter shunt. The circuit breakers should be accessible in flight and labeled respectively: "LEFT GEN. CIRCUIT" and "RIGHT GEN. CIRCUIT."