| AD Number | 71-19-02 | Status | Active |
| Effective Date | September 27, 1971 | Issue Date | Not specified |
| Docket Number | Unknown | Amendment | 39-1281 |
| Product Type | ["Aircraft"] | Product Subtype | ["Large Airplane"] |
| CFR Part | --- - Part 39 | CFR Section | N/A |
| Citation | This information is not available. | ||
| Manufacturer(s) | Sud Aviation |
| Model(s) | Caravelle SE 210 Model VIR |
71-19-02 SOCIETE NATIONAL INDUSTRIELLE AEROSPATIALE (S.N.I.A.S.): Amendment 39-1281. Applies to Sud Model SE.210, MK. V1-R "Caravelle" airplanes.
To prevent a possible fire due to unnoticed overheating of a hydraulic system, within the next 500 hours' time in service after the effective date of this AD, unless already accomplished, incorporate S.A. Modification 1262 by installing a Green and Blue Hydraulic System Fluid Overheat Detection System in accordance with Sud Service-Caravelle Bulletin No. 29-70, Revision 10, dated October 12, 1970, or later SGAC-approved issue or an FAA-approved equivalent.
This amendment becomes effective September 27, 1971.