Back to AD

AD 69-25-02 ACTIVE

Generator Control Panels
Key Information
AD Number 69-25-02 Status Active
Effective Date January 03, 1970 Issue Date Not specified
Docket Number Unknown Amendment 39-883
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) The Boeing Company
Model(s) 727-100 Series 727-100C Series 727-200 Series 727-200F Series 727 Series 727C Series
Regulatory Text

69-25-02\tBOEING: Amdt. 39-883. Applies to Model 727 series airplanes. \n\n\tCompliance within the next 2500 hours time in service after the effective date of this AD unless already accomplished. \n\n\tTo prevent generator system lockout, accomplish the following or an equivalent modification approved by the Chief, Aircraft Engineering Division, FAA Western Region: \n\n\tModify the generator control panels in accordance with Part II, Paragraph A and C of Westinghouse Service Bulletin No. 66-103, dated September 15, 1966, and the supplement dated September 30, 1966, or later FAA approved revisions. \n\n\tThis amendment becomes effective January 3, 1970.