Back to AD

AD 2016-06-05 ACTIVE

Nacelles/Pylons
Key Information
AD Number 2016-06-05 Status Active
Effective Date April 22, 2016 Issue Date March 09, 2016
Docket Number FAA-2015-2459 Amendment 39-18436
Product Type ["Aircraft"] Product Subtype ["Large Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation (Federal Register Volume 81, Number 53 (Friday, March 18, 2016))
Applicability
Manufacturer(s) The Boeing Company
Model(s) 777-200 Series 777-200LR Series 777-300 Series 777-300ER Series 777F Series
Summary

We are adopting a new airworthiness directive (AD) for certain The Boeing Company Model 777 airplanes. This AD was prompted by reports of fire and smoke at the engine aft pylon area resulting from fuel leakage caused by a damaged O-ring in the fuel coupling attached to the wing front spar. This AD requires applying sealant to fill the gap between the lower wing panels adjacent to the strut aft vapor barrier. We are issuing this AD to prevent fire and smoke at the engine aft pylon area in the event of a fuel leak, which could cause personal injury during ground operations. A fire spreading back and up to the aft fairing pylon can result in an uncontrolled fire in the strut and ignite the fuel tank.

Action Required

Final rule.

Regulatory Text

Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2016-06-05 The Boeing Company: Amendment 39-18436; Docket No. FAA- 2015-2459; Directorate Identifier 2015-NM-002-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective April 22, 2016. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to The Boeing Company Model 777-200, -200LR, - 300, -300ER, and -777F series airplanes, certificated in any category, as identified in Boeing Special Attention Service Bulletin 777-54-0035, dated October 30, 2014. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 54, Nacelles/ Pylons. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of fire and smoke at the engine aft pylon area resulting from fuel leakage caused by a damaged O- ring in the fuel coupling attached to the wing front spar. We are issuing this AD to prevent fire and smoke at the engine aft pylon area in the event of a fuel leak, which could cause personal injury during ground operations. A fire spreading back and up to the aft fairing pylon can result in an uncontrolled fire in the strut and ignite the fuel tank. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Sealant Application \n\n\n\tWithin 1,875 days after the effective date of this AD, apply sealant to fill the gap between the lower wing panels adjacent to the strut aft vapor barrier, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-54- 0035, dated October 30, 2014. \n\n((Page 14700)) \n\n(h) Alternative Methodsof Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (i)(1) of this AD. Information may be emailed to: 9-ANM-Seattle-ACO-AMOC-Requests@faa.gov. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) For service information that contains steps that are labeled as Required for Compliance (RC), the provisions of paragraphs (h)(3)(i) and (h)(3)(ii) apply. \n\t(i) The steps labeled as RC, including substeps under an RC step andany figures identified in an RC step, must be done to comply with the AD. An AMOC is required for any deviations to RC steps, including substeps and identified figures. \n\t(ii) Steps not labeled as RC may be deviated from using accepted methods in accordance with the operator's maintenance or inspection program without obtaining approval of an AMOC, provided the RC steps, including substeps and identified figures, can still be done as specified, and the airplane can be put back in an airworthy condition. \n\t(4) An AMOC that provides an acceptable level of safety may be used for any repair required by this AD if it is approved by the Boeing Commercial Airplanes Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO, to make those findings. For a repair method to be approved, the repair must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\n(i) Related Information \n\n\n\t(1) For more information about this AD, contact Kevin Nguyen, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office (ACO), 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6501; fax: 425-917-6590; email: kevin.nguyen@faa.gov. \n\t(2) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544- 5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. You may view this referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\n(j) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Special Attention Service Bulletin 777-54-0035, dated October 30, 2014. \n\t(ii) Reserved. \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544- 5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. \n\t(4) You may view this referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Supplementary Information

Discussion \n\n\n\tWe issued a notice of proposed rulemaking (NPRM) to amend 14 CFR part 39 by adding an AD that would apply to certain The Boeing Company Model 777 airplanes. The NPRM published in the Federal Register on July 9, 2015 (80 FR 39392). The NPRM was prompted by reports of fire and smoke at the engine aft pylon area resulting from fuel leakage caused by a damaged O ring in the fuel coupling attached to the wing front spar. The fuel was captured by the fuel coupling rubber boot and was discharged into the flammable fluid leakage zone of the strut-to-wing cavity, as intended. However, the fuel did not follow its intended drain paths into the aft strut and lower wing panel drains, but instead followed an unintended drain path through an unsealed gap between the lower wing panels above the strut aft vapor barrier. The leaking fuel then followed gaps and seams in the aft fairing structure to the outside of the strut fairing side panels, ignited after \n\n((Page 14699)) \n\ncontact with the hot engine exhaust heat shield, and caused a fire and smoke. We are issuing this AD to prevent fire and smoke at the engine aft pylon area in the event of a fuel leak, which could cause personal injury during ground operations. A fire spreading back and up to the aft fairing pylon can result in an uncontrolled fire in the strut and ignite the fuel tank. \n\nComments \n\n\n\tWe gave the public the opportunity to participate in developing this AD. We have considered the comments received. Boeing concurred with the NPRM (80 FR 39392, dated July 9, 2015), and FedEx had no technical objection. \n\nConclusion \n\n\n\tWe reviewed the relevant data, considered the comments received, and determined that air safety and the public interest require adopting this AD as proposed--except for minor editorial changes. We have determined that these minor changes: \n\tAre consistent with the intent that was proposed in the NPRM (80 FR 39392, dated July 9, 2015) forcorrecting the unsafe condition; and \n\tDo not add any additional burden upon the public than was already proposed in the NPRM (80 FR 39392, dated July 9, 2015). \n\nRelated Service Information Under 1 CFR Part 51 \n\n\n\tWe have reviewed Boeing Special Attention Service Bulletin 777-54- 0035, dated October 30, 2014. The service information describes procedures for applying sealant to fill the gap between wing panels. This service information is reasonably available because the interested parties have access to it through their normal course of business or by the means identified in the ADDRESSES section. \n\nCosts of Compliance \n\n\n\tWe estimate that this AD affects 196 airplanes of U.S. registry. \n\tWe estimate the following costs to comply with this AD: \n\n\n\tEstimated Costs ---------------------------------------------------------------------------------------------------------------- \n\tCost per Cost on U.S. \n\tAction Labor cost Parts costproduct operators ---------------------------------------------------------------------------------------------------------------- Sealant application............... 3 work-hours x $85 per $0 $255 $49,980 \n\thour = $255. ---------------------------------------------------------------------------------------------------------------- \n\nAuthority for This Rulemaking \n\n\n\tTitle 49 of the United States Code specifies the FAA's authority to issue rules on aviation safety. Subtitle I, section 106, describes the authority of the FAA Administrator. Subtitle VII: Aviation Programs, describes in more detail the scope of the Agency's authority. \n\tWe are issuing this rulemaking under the authority described in Subtitle VII, Part A, Subpart III, Section 44701: ''General requirements.'' Under that section, Congress charges the FAA with promoting safe flight of civil aircraft in air commerce by prescribing regulations for practices, methods, and procedures the Administrator finds necessary for safety in air commerce. This regulation is within the scope of that authority because it addresses an unsafe condition that is likely to exist or develop on products identified in this rulemaking action. \n\nRegulatory Findings \n\n\n\tThis AD will not have federalism implications under Executive Order 13132. This AD will not have a substantial direct effect on the States, on the relationship between the national government and the States, or on the distribution of power and responsibilities among the various levels of government. \n\tFor the reasons discussed above, I certify that this AD: \n\t(1) Is not a ''significant regulatory action'' under Executive Order 12866, \n\t(2) Is not a ''significant rule'' under DOT Regulatory Policies and Procedures (44 FR 11034, February 26, 1979), \n\t(3) Will not affect intrastate aviation in Alaska, and \n\t(4) Will not have a significant economic impact, positive or negative, on a substantial number ofsmall entities under the criteria of the Regulatory Flexibility Act. \n\nList of Subjects in 14 CFR Part 39 \n\n\n\tAir transportation, Aircraft, Aviation safety, Incorporation by reference, Safety.

Addresses

For service information identified in this final rule, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. You may view this referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. It is also available on the Internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2015- 2459. \n\nExamining the AD Docket \n\n\n\tYou may examine the AD docket on the Internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2015- 2459; or in person at the Docket Management Facility between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The AD docket contains this AD, the regulatory evaluation, any comments received, and other information. The address for the Docket Office (phone: 800-647- 5527) is Docket Management Facility, U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590.

For Further Information Contact

Kevin Nguyen, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office (ACO), 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917- 6501; fax: 425-917-6590; email: kevin.nguyen@faa.gov.