Back to AD

AD 79-04-04 ACTIVE

Charging Circuit Fire Hazard
Key Information
AD Number 79-04-04 Status Active
Effective Date February 23, 1979 Issue Date Not specified
Docket Number Unknown Amendment 39-3416
Product Type ["Aircraft"] Product Subtype ["Small Airplane"]
CFR Part --- - Part 39 CFR Section N/A
Citation This information is not available.
Applicability
Manufacturer(s) Taylorcraft 2000, LLC
Model(s) F19
Regulatory Text

79-04-04\tTAYLORCRAFT AVIATION CORPORATION: Amendment 39-3416. Applies to Taylorcraft Model F-19 aircraft, serial numbers 001 through 112, 115 through 130, and 132. \n\nCompliance is required as indicated. To prevent fire hazard in the charging circuit, accomplish the following: \n\nThis AD must be accomplished prior to next 50 hours time in service after the effective date of this AD or by July 1, 1979, whichever occurs first. \n\nRemove the 12 gauge wire, identified as P/N -10, which connects the starter solenoid "battery terminal" with the master switch. Use Mil Spec MilC7078 or equivalent 8 gauge shielded wire, to fabricate a cable in the same manner as the 8 gauge cable from the alternator to the ammeter. Use appropriate wire terminals. Attach this cable to the ignition switch terminal of the ammeter. Route this 8 gauge wire through the opening in the firewall where the 12 gauge wire previously ran and attach it to the starter solenoid "battery terminal". (See attached wiring diagram.) \n\nThis amendment becomes effective February 23, 1979. \n\n\nAD 79-04-04