AD 79-04-04

Active

Charging Circuit Fire Hazard

Key Information
79-04-04
Active
February 23, 1979
Not specified
Unknown
39-3416
Applicability
["Aircraft"]
["Small Airplane"]
Taylorcraft 2000, LLC
F19
Regulatory Text

79-04-04\tTAYLORCRAFT AVIATION CORPORATION: Amendment 39-3416. Applies to Taylorcraft Model F-19 aircraft, serial numbers 001 through 112, 115 through 130, and 132. \n\nCompliance is required as indicated. To prevent fire hazard in the charging circuit, accomplish the following: \n\nThis AD must be accomplished prior to next 50 hours time in service after the effective date of this AD or by July 1, 1979, whichever occurs first. \n\nRemove the 12 gauge wire, identified as P/N -10, which connects the starter solenoid "battery terminal" with the master switch. Use Mil Spec MilC7078 or equivalent 8 gauge shielded wire, to fabricate a cable in the same manner as the 8 gauge cable from the alternator to the ammeter. Use appropriate wire terminals. Attach this cable to the ignition switch terminal of the ammeter. Route this 8 gauge wire through the opening in the firewall where the 12 gauge wire previously ran and attach it to the starter solenoid "battery terminal". (See attached wiring diagram.) \n\nThis amendment becomes effective February 23, 1979. \n\n\nAD 79-04-04