2002-09-05 Bombardier, Inc. (Formerly de Havilland, Inc.): Amendment 39-12738. Docket 2001-NM-49-AD.
Applicability: Model CL-600-2B19 series airplanes, serial numbers 7003 through 7295 inclusive; certificated in any category.
Note 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (d) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.
Compliance: Required as indicated, unless accomplished previously.
To detect and correct inadequate clearance between the fuel-level sensing wires in the center fuel tank and adjacent structures, which could lead to chafing of the wires, resulting in electrical arcing between the fuel-level sensing wires and the center fuel tank and a consequent fire or explosion in the center fuel tank, accomplish the following:
Inspection
(a) At the next "A" check but no later than 500 flight hours after the effective date of this AD: Perform a general visual inspection of the fuel-level sensing wires in the center fuel tank for damage and for clearance from adjacent structures, in accordance with Bombardier Alert Service Bulletin 601R-28-042, Revision 'A,' dated January 12, 2001. If the inspection reveals that the clearance between the fuel-level sensing wires and adjacent structures is less than the minimum clearance specified in the service bulletin, prior to further flight, adjust the clearance in accordance with the service bulletin.
Note 2: For the purposes of this AD, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or drop-light, and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked."
Note 3: Inspection, adjustment of the clearance between the fuel-level sensing wires and adjacent structures, and replacement of damaged fuel-level sensing wires accomplished prior to the effective date of this AD, in accordance with Bombardier Alert Service Bulletin 601R-28-042, dated August 14, 2000, are considered acceptable for compliance with the applicable action specified in this AD.
Replacement
(b) If the inspection required by paragraph (a) of this AD reveals damage to the fuel-level sensing wires: Prior to further flight, replace the damaged fuel-level sensing wires having part number (P/N) 601R57137-1/01 with new, improved fuel-level sensing wires having P/N 601R57137-1/S01, in accordance with Bombardier Alert Service Bulletin 601R-28-042, Revision 'A,' dated January 12, 2001.
Installation of Cushioned Clamps
(c) Prior to further flight after accomplishing the actions required by paragraphs (a) and (b) of this AD, if applicable: Install cushioned clamps between pipe P/N 601R62261-55 and the fuel-level sensing wires, in accordance with Bombardier Alert Service Bulletin 601R-28-042, Revision `A,' dated January 12, 2001.
Alternative Methods of Compliance
(d) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, New York Aircraft Certification Office (ACO), FAA. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, New York ACO.
Note 4: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the New York ACO.
Special Flight Permits
(e) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
Incorporation by Reference
(f) The actions shall be done in accordance with Bombardier Alert Service Bulletin 601R-28-042, Revision `A,' dated January 12, 2001. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, Station Centre-ville, Montreal, QuebecH3C 3G9, Canada. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, New York Aircraft Certification Office, 10 Fifth Street, Third Floor, Valley Stream, New York; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
Note 5: The subject of this AD is addressed in Canadian airworthiness directive CF-2000-31, dated October 4, 2000.
Effective Date
(g) This amendment becomes effective on June 6, 2002.