2001-25-01 McDonnell Douglas: Amendment 39-12553. Docket 2001-NM-345-AD. \n\n\tApplicability: Model DC-8-33, -43, -51, -52, -53, and -55 series airplanes; Model DC-8F-54, and -55 series airplanes; and Model DC-8-61, -61F, -62, -62F, -63, -63F, -71, -71F, -72, -72F, -73, and -73F series airplanes; certificated in any category; as listed in Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001. \n\n\tNote 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe conditionaddressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it. \n\n\tCompliance: Required as indicated, unless accomplished previously. \n\n\tTo detect and correct cross-wired electrical connectors of the fire extinguishing system, which could release fire extinguishing agent into the incorrect engine nacelle in the event of an engine fire, accomplish the following: \n\nRepetitive Inspections and Tests, and Corrective Action(s), if Necessary \n\n\t(a) Within 30 days after the effective date of this AD, do the action(s) specified in paragraphs (a)(1) and (a)(2) of this AD per Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001. \n\n\t\t(1) Do an inspection of the electrical connectors of the explosive cartridge wiring of the engine fire extinguisher containers to verify if the identification number labels are installed and legible. If any identification number label is missing or is not legible, before further flight, install a label or replace the label with a new label, as applicable. Repeat the inspection after each maintenance action for the Firex Discharge system. \n\n\t\t(2) Do an electrical test of all explosive cartridge wiring of the engine fire extinguisher containers to verify proper installation and function, using the cockpit warning lamps. If the lamp fails to illuminate, before further flight, troubleshoot and repair the wiring of the Firex Discharge system. Repeat the test after each maintenance action for the Firex Discharge system. \n\n\tNote 2: Inspections, tests, and corrective actions, if necessary, done per Boeing BOECOM M-7200-01-02632, dated November 5, 2001, before the effective date of this AD, are considered acceptable for compliance with the requirements of this AD. \n\nAlternative Methods of Compliance \n\n\t(b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved bythe Manager, Los Angeles Aircraft Certification Office (ACO), FAA. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Los Angeles ACO. \n\n\tNote 3: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Los Angeles ACO. \n\nSpecial Flight Permits \n\n\t(c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished. \n\nIncorporation by Reference \n\n\t(d) The actions shall be done in accordance with Boeing Alert Service Bulletin DC8-26A046, dated November 7, 2001. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Boeing Commercial Aircraft Group, Long Beach Division, 3855 Lakewood Boulevard, Long Beach, California 90846, Attention: Data and Service Management, Dept. C1-L5A (D800-0024). Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, Los Angeles Aircraft Certification Office, 3960 Paramount Boulevard, Lakewood, California; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. \n\nEffective Date \n\n\t(e) This amendment becomes effective on December 20, 2001.