2001-21-06 Gulfstream Aerospace Corporation: Amendment 39-12477. Docket 2001-NM-305-AD.
Applicability: Model G-V series airplanes, serial numbers 501 through 652 inclusive; certificated in any category.
Note 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (e) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.
Compliance: Required as indicated, unless accomplished previously.
To prevent fire extinguishing agent from being discharged into the wrong location, which could result in failure to extinguish an in-flight fire on an affected engine and jeopardize operation of the opposite engine, accomplish the following:
Inspections
(a) Within the next 25 flight hours, but no later than 10 days after the effective date of this AD: Perform a general visual inspection of the electrical connections of the fire extinguisher bottles for correct connections, in accordance with Gulfstream Alert Customer Bulletin No. 14, dated September 20, 2001.
(b) Prior to further flight following any maintenance that affects the fire extinguisher bottles: Perform the inspection required by paragraph (a) of this AD.
Note 2: For the purposes of this AD, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or drop-light, and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked."
Corrective Action
(c) If any incorrect electrical connection is detected during the inspections required by paragraph (a) or (b) of this AD: Correct that connection, in accordance with the Accomplishment Instructions of Gulfstream Alert Customer Bulletin No. 14, dated September 20, 2001.
Reporting
(d) Submit a report of inspection findings (both positive and negative) to the Manager, Atlanta Aircraft Certification Office (ACO), FAA, One Crown Center, 1895 Phoenix Boulevard, suite 450, Atlanta, Georgia 30349; fax (770) 703-6097; at the applicable time specified in paragraph (d)(1) or (d)(2) of this AD. The report must include the inspection results, a description of any discrepancies found, the airplane serial number, and the number of landings and flight hours on the airplane. Information collection requirements contained in this regulation have been approved by the Office of Management and Budget (OMB) under the provisions of the Paperwork Reduction Act of 1980 (44 U.S.C. 3501 et seq.) and have been assigned OMB Control Number 2120-0056.
(1) For airplanes on which the inspection required by paragraph (a) of this AD is accomplished after the effective date of this AD: Submit the report within 35 days after performing the inspection required by paragraph (a) of this AD.
(2) For airplanes on which the inspection required by paragraph (a) of this AD has been accomplished prior to the effective date of this AD: Submit the report within 35 days after the effective date of this AD.
Alternative Methods of Compliance
(e) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Atlanta ACO. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Atlanta ACO.
Note 3: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Atlanta ACO.
Special Flight Permits
(f) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
Incorporation by Reference
(g) The actions shall be done in accordance with Gulfstream V Alert Customer Bulletin No. 14, dated September 20, 2001. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Gulfstream Aerospace Corporation, P.O. Box 2206, M/S D-10, Savannah, Georgia 31402-9980. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, Atlanta Aircraft Certification Office, One Crown Center, 1895 Phoenix Boulevard, suite 450, Atlanta, Georgia; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
Effective Date
(h) This amendment becomes effective on November 6, 2001.