2000-18-03 Rolls-Royce plc: Amendment 39-11888. Docket 2000-NE-23-AD.
Applicability:
This airworthiness directive (AD) applies to Rolls-Royce plc RR) models RB211-524D4-19, -524D4-B-19, -524D4-B-39, -524D4X-19, and -524D4X-B-19 turbofan engines with cold stream nozzle assembly Part Number (PN) LJ32826 installed. These engines are installed on, but not limited to, Boeing 747-200 and -300 series airplanes.
Note 1: This AD applies to each engine identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For engines that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (d) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.
Compliance:
Compliance with this AD is required as indicated, unless already done. To detect cracks that could result in the failure of the cold stream nozzle assembly, which could result in possible release of cold stream nozzle debris from the engine and possible impact damage to airplane control surfaces, perform the following inspections:
Initial Inspection
(a) Inspect cold stream nozzle assemblies for cracks within 60 days or 100 cycles-in-service (CIS) after the effective date of this AD, whichever is sooner, in accordance with the Accomplishment Instructions, Sections 3.A through 3.C.(3) of RR Service Bulletin (SB) RB.211-78-C955, Revision 1, dated June 20, 2000.
Repetitive Inspections
(b) Thereafter, inspect each nozzle assembly for cracks within 1400 CIS since last inspection in accordance with AccomplishmentInstructions, Sections 3.A. through 3.C.(3) of RR SB RB.211-78-C955, Revision 1.
Optional Terminating Action
(c) Repair of cold stream nozzle assemblies PN LJ32826 on both left and right sides in accordance with RR SB RB.211-78-C955, Revision 1, dated June 20, 2000, is considered terminating action for the repetitive inspection requirements of this AD.
Alternative Methods of Compliance
(d) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Engine Certification Office (ECO). Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, ECO.
Note 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the ECO.
Special Flight Permits
(e) Special flight permits may be issued in accordance with sections21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
Incorporation by Reference
(f) The actions required by this AD shall be performed in accordance with the following RR SB:
Document No.
Pages
Revision
Date
RB.211-78-C955
1-5
1
June 20, 2000
Total pages: 5
This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Rolls-Royce plc, PO Box 31, Derby, England; telephone: International Access Code 011, Country Code 44, 1332-249428, fax: International Access Code 011, Country Code 44, 1332-249223. Copies may be inspected at the FAA, New England Region, Office of the Regional Counsel, 12 New England Executive Park, Burlington, MA; or at the Office of the Federal Register, 800 North Capitol Street, NW, suite 700, Washington, DC.
Effective Date
(g) This amendment becomes effective on September 22, 2000.
FOR FURTHER INFORMATION CONTACT: James Lawrence, Aerospace Engineer, Engine Certification Office, FAA, Engine and Propeller Directorate, 12 New England Executive Park, Burlington, MA 01803-5299; telephone: (781)-238-7176, fax: (781)-238-7199.