94-24-06 RAYTHEON CORPORATE JETS, INC. (FORMERLY DEHAVILLAND, HAWKER SIDDLEY, BRITISH AEROSPACE PLC): Amendment 39-9079. Docket 94-NM-74-AD.
Applicability: All Model BH/HS 125-600A and -700A series airplanes, certificated in any category.
NOTE 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must use the authority provided in paragraph (b) to request approval from the FAA. This approval may address either no action, if the current configuration eliminates the unsafe condition; or different actions necessary to address the unsafe condition described in this AD. Such a request should include an assessment of the effect of the changed configuration on the unsafe condition addressed by this AD. In no case does the presence of any modification, alteration, or repair remove any airplane from the applicability of this AD.
Compliance: Required as indicated, unless accomplished previously.
To prevent smoke or fire in the flight deck due to short circuiting of the flight deck lighting transformers 6V output circuits, accomplish the following:
(a) Within six months after the effective date of this AD, install circuit breakers in two 6 volt output circuits of the flight deck lighting transformers in accordance with Hawker - Raytheon Corporate Jets Service Bulletin SB.24-310-3544A&B, dated February 14, 1994.
(b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Standardization Branch, ANM-113, FAA, Transport Airplane Directorate. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who mayadd comments and then send it to the Manager, Standardization Branch, ANM-113.
NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Standardization Branch, ANM-113.
(c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
(d) The installation shall be done in accordance with Hawker - Raytheon Corporate Jets Service Bulletin SB.24-310-3544A&B, dated February 14, 1994. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Raytheon Corporate Jets, Inc., Customer Support Department, Adams Field, P.O. Box 3356, Little Rock, Arkansas 72203. Copies may be inspected at the FAA, Transport AirplaneDirectorate, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
(e) This amendment becomes effective on January 4, 1995.