95-02-09 BRITISH AEROSPACE (COMMERCIAL AIRCRAFT), LIMITED: Amendment 39-9128. Docket 93-NM-217-AD.
Applicability: Model ATP airplanes equipped with Ferranti Transformer Rectifier Unit TR202A (Pt. No. 84/59100) or TR202B (Pt. No. 84/60040), certificated in any category.
NOTE 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must use the authority provided in paragraph (b) to request approval from the FAA. This approval may address either no action, if the current configuration eliminates the unsafe condition; or different actions necessary to address the unsafe condition described in this AD. Such a request should include an assessment of the effect of the changed configuration on the unsafe condition addressed by this AD. In no case does the presence of any modification, alteration, or repair remove any airplane from the applicability of this AD.
Compliance: Required as indicated, unless accomplished previously.
To prevent loss of essential electrical power required to continue safe flight of the airplane, accomplish the following:
(a) Within 225 hours time-in-service after the effective date of this AD, and thereafter at intervals not to exceed 625 hours time-in-service, accomplish paragraphs (a)(1), (a)(2), (a)(3), and (a)(4) of this AD.
(1) Perform a visual inspection of the DC connections to detect any damage or overheating, in accordance with Ferranti Service Bulletin 24-20-171, dated September 1993. If any damage or overheating is found, prior to further flight, repair in accordance with a method approved by Manager, Standardization Branch, ANM-113, FAA, Transport Airplane Directorate.
(2) Perform a torque loading inspection of each DC connection to ensure that torque loads are within the limits specified in Ferranti Service Bulletin 24-20-171, dated September 1993; and, during this inspection, ensure that each terminal stud is secure in its mounting by visually observing that the stud does not rotate; in accordance with Ferranti Service Bulletin 24-20-171, dated September 1993.
(3) Perform a visual inspection of the cooling fan blades to detect any damage due to overheating, in accordance with Ferranti Service Bulletin 24-20-172, dated September 1993. If any damage is found, prior to further flight, replace the fan blade with a serviceable part in accordance with the airplane maintenance manual.
(4) Perform a functional test of the operation of the cooling fan by energizing the relay and confirming that cooling air exits from the grill on top of the unit, in accordance with Ferranti Service Bulletin 24-20-172, dated September 1993. Prior to further flight, repair or replace any malfunctioning or damaged cooling fan or cooling fan relay, in accordance with the airplane maintenance manual.
(b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Standardization Branch, ANM-113, FAA, Transport Airplane Directorate. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Standardization Branch, ANM-113.
NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Standardization Branch, ANM-113.
(c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
(d) The inspections and test shall be done in accordance with Ferranti Service Bulletin 24-20-171, dated September 1993; and Ferranti Service Bulletin 24-20-172, dated September 1993. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Jetstream Aircraft, Inc., P.O. Box 16029, Dulles International Airport, Washington, DC 20041-6029. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
(e) This amendment becomes effective on March 16, 1995.