AD 82-25-05

Active

Terminal Wiring on the D.C. Generator Outputs

Key Information
82-25-05
Active
December 06, 1982
Not specified
Unknown
39-4504
Applicability
["Aircraft"]
["Large Airplane"]
Mitsubishi Heavy Industries, Ltd.
YS-11 YS-11A-200 YS-11A-300 YS-11A-500 YS-11A-600
Regulatory Text

82-25-05 NIHON AEROPLANE MANUFACTURING COMPANY: Amendment 39- 4504. Applies to Model YS-11/11A series airplanes, certificated in all categories. Compliance required within the next 250 hours time in service or 90 days, whichever occurs first, after the effective date of this AD, unless previously accomplished. To prevent the loss of both D.C. generator outputs:

1. Modify the terminal wiring on the D.C. generators in accordance with the Accomplishment Instructions of Lear Siegler, Inc., Service Bulletin No. 30029-02 dated November 16, 1980.

2. Alternate means of compliance which provide an equivalent level of safety may be used when approved by the Manager, Seattle Aircraft Certification Office, FAA, Northwest Mountain Region.

3. Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate airplanes to a base for the accomplishment of inspections and/or modifications required by this AD.

The manufacturer's specifications and proceduresidentified and described in this directive are incorporated herein and made a part hereof pursuant to 5 U.S.C. 552(a)(1).

This amendment becomes effective December 6, 1982.