AD 79-21-09 R1

Active

Electrical System

Key Information
79-21-09 R1
Active
June 08, 1981
Not specified
Unknown
39-4128
Applicability
["Aircraft"]
["Small Airplane"]
Revo, Incorporated
Colonial C-1 Colonial C-2 Lake LA-4 Lake LA-4-200 Lake LA-4A Lake LA-4P
Regulatory Text

79-21-09 R1 CONSOLIDATED AERONAUTICS: Amendment 39-3589 is further amended by Amendment 39-4128. Applies to Colonial C-1, Colonial C-2, Lake LA-4, Lake LA-4A, Lake LA-4P, and Lake LA-4-200 airplanes with an anchor light or bilge pump installed with a power line which bypasses the battery relay.

Compliance required within the next 50 hours time in service unless already accomplished.

To preclude burning of power wires in case of an electrical short, install a Cole-Hersee 3031-D fuse holder and a Buss AG5A 5 ampere fuse, or FAA approved equivalents, within 4 inches of the battery relay, in the power lines for the anchor light and bilge pump.

(Lake Aircraft Division, Consolidated Aeronautics Service Bulletin B-62 pertains to the installation required by this AD.)

Upon request, an equivalent method of compliance with the requirements of this AD may be approved by the Chief, Engineering and Manufacturing Branch, Federal Aviation Administration, New England Region.

Amendment 39-3589 became effective upon publication in the FEDERAL REGISTER.

This Amendment, 39-4128, becomes effective June 8, 1981.