AD 70-06-07

Active

Relay for APU Oil Pump

Key Information
70-06-07
Active
April 18, 1970
Not specified
Unknown
39-958
Applicability
["Aircraft"]
["Large Airplane"]
Dassault Aviation
Fan Jet Falcon
Regulatory Text

70-06-07 AVIONS MARCEL DASSAULT/SUD-AVIATION: Amdt. 39-958. Applies to all series Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.

Compliance is required within the next 75 hours of APU operation, unless already accomplished.

To prevent a fire hazard due to continued operation of the APU oil pump motor after APU shutdown, replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A in accordance with Microturbo Saphir I Service Bulletin 49.10.39, dated September 30, 1969; or Microturbo Saphir II Service Bulletin 49.11.08, Revision No. 1, dated September 30, 1969, as applicable, or later SGAC-approved issues, or FAA-approved equivalents.

This amendment becomes effective April 18, 1970.