70-06-07 AVIONS MARCEL DASSAULT/SUD-AVIATION: Amdt. 39-958. Applies to all series Fan Jet Falcon airplanes with Microturbo Saphir I and II APU's installed.
Compliance is required within the next 75 hours of APU operation, unless already accomplished.
To prevent a fire hazard due to continued operation of the APU oil pump motor after APU shutdown, replace Equipment Construction Electrique (ECE) relay P/N 1475-7 with ECE contactor P/N 100CC01-A in accordance with Microturbo Saphir I Service Bulletin 49.10.39, dated September 30, 1969; or Microturbo Saphir II Service Bulletin 49.11.08, Revision No. 1, dated September 30, 1969, as applicable, or later SGAC-approved issues, or FAA-approved equivalents.
This amendment becomes effective April 18, 1970.