AD 59-26-02

Active

Two Fuel Cell Vent Tubes

Key Information
59-26-02
Active
Not specified
December 14, 1959
Unknown
N/A
Applicability
["Aircraft"]
["Small Airplane"]
Piper Aircraft Inc.
PA-24 PA-24-250
Regulatory Text

59-26-02 PIPER: Applies to PA-24 and PA-24 "250" Airplanes Serial Numbers 24-1 To 24-1373 Inclusive.

Compliance required by January 15, 1960.

To prevent clogging, the two fuel cell vent tubes which are located under the wings shall be modified in the following manner:

Measure a distance of 1/2-inch down from the bottom of the wing skin along the forward side of each protruding vent tube. At this point, cut the tube off at a 45-degree angle to the bottom skin so that the end of the tube remains square.

(Piper Immediate Action Service Bulletin No. 180 covers this subject.)