AD 55-09-01

Active

Magnetic Circuit Breaker

Key Information
55-09-01
Active
Not specified
December 04, 1956
Unknown
N/A
Applicability
["Aircraft"]
["Large Airplane"]
Aero Spacelines Incorporated
377 377MG 377SGT
Regulatory Text

55-09-01 BOEING: Applies to all Model 377 aircraft with Hamilton Standard Propellers.
To be accomplished as soon as practicable but not later than June 30, 1955.
Loss of manual r.p.m. control can occur as a result of tripping of the fast-acting magnetic circuit breaker before the slow-acting fuse is blown on a faulted branch. Improved circuit protective coordination and resultant reliability in the manual control function should be provided by replacing the "Manual" 10-ampere magnetic circuit breaker with a 5-ampere thermal type breaker, and replacing the four 5-ampere fuses in the synchronizer unit with 2 ampere Slo-Blo fuses.
(Hamilton Standard Service Bulletin No. 283 dated December 21, 1953, covers this same subject.)