Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive: \n\n2021-08-16 PZL Swidnik S.A.: Amendment 39-21510; Docket No. FAA- 2021-0299; Project Identifier MCAI-2020-00253-R. \n\n(a) Effective Date \n\n\n\tThis airworthiness directive (AD) is effective May 11, 2021. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to PZL Swidnik S.A. (PZL) Model W-3A helicopters, certificated in any category, with a Collins Aerospace (formerly Goodrich) electric hoist (hoist) part number (P/N) 76378- 500 with a stainless steel cable (cable) P/N 712952 installed. \n\n(d) Subject \n\n\n\tJoint Aircraft Service Component (JASC) Code: 2597, Equip/ Furnishing System Wiring. \n\n(e) Unsafe Condition \n\n\n\tThis AD defines the unsafe condition as wear and reduction of the cable diameter near the swaged terminal due to movement of the hook assembly. This condition could result in reduced strength of the cable, potentially resulting in an in-flight loss of the hoist load, injury to persons, and reduced control of or damage to the helicopter. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless accomplished previously. \n\n(g) Required Actions \n\n\n\t(1) Within 25 hours time-in service on the hoist (hoist hours) after the effective date of this AD, and thereafter at intervals not to exceed 25 hoist hours: \n\t(2) Remove the bottom part of the hook assembly, disengage and lift the hook assembly, clean the cable near the swaged terminal, and visually inspect for wear and damage. For the purposes of this AD, damage may be indicated by broken wires, kinks, bird cages, flattened areas, abrasion, necking, corrosion, or fretting. Visually inspect the area at no less than 12 cm of the cable between the cable swaged terminal and the hook assembly, as depicted in Figures 2 and 3 of Goodrich Actuation Systems Alert Service Bulletin 76378- 500-25-P01, Revision 0, dated December 3, 2019 (ASB 76378-500-25- P01). \n\t(i) If the cable is worn or damaged, before the next hoist operation, remove the cable from service and replace with an airworthy part. Within 30 calendar days, email the non-compliant information in accordance with paragraph 3.A.(4)(a) of ASB 76378- 500-25-P01 to PL-CustomerSupport.AW@leonardocompany.com. \n\t(ii) If there is no damage, before the next hoist operation, inspect the cable diameter restriction on the 12 cm length ensuring the cable diameter is >=4.60 mm (0.181 in) paying particular attention to the cable diameter which is approximately 1 cm from the cable swaged terminal. \n\t(iii) If the cable diameter is less than 4.60 mm (0.181 in), before the next hoist operation, replace the cable with an airworthy part. Within 30 calendar days, email the non-complaint information in accordance with paragraph 3.B.(1)(f) of ASB 76378-500-25-P01 to PL-CustomerSupport.AW@leonardocompany.com. \n\t(iv) If the cable diameter is >=4.60 mm (0.181 in), lubricate the cable with oil MIL-L-23699 or MIL-L-7808, or equivalent, reassemble bottom part of the hook assembly on the upper part, and bring the hook assembly back to the stowage position. \n\t(3) As of the effective date of this AD, do not install a hoist or cable with a P/N identified in paragraph (c) of this AD unless they meet the conditions as required by paragraph (g) of this AD. \n\n(h) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, International Validation Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or localFlight Standards District Office, as appropriate. If sending information directly to the manager of the International Validation Branch, send it to the attention of the person identified in paragraph (i)(1) of this AD. Information may be emailed to: 9-AVS-AIR-730-AMOC@faa.gov. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\n(i) Related Information \n\n\n\t(1) For more information about this AD, contact Kristi Bradley, Aerospace Engineer, General Aviation & Rotorcraft Section, International Validation Branch, FAA, 10101 Hillwood Pkwy., Fort Worth, TX 76177; telephone 817-222-5110; email kristin.bradley@faa.gov. \n\t(2) WYTWORNIA SPRZETU KOMUNIKACYJNEGO ''PZL- Swidnik'' Spolka Akcyjna Mandatory Alert Service Bulletin No. BO-37-19-309, dated January 28, 2020, which is not incorporated by reference, contains additional information about the subject of this AD. For service information identified in this AD, contact WSK ''PZL-Swidnik'' S.A., Al. Lotnikow Polskich 1, 21-045 Swidnik, Poland; telephone +48-664 424 798; fax (+48) 817 225 710; or at www.pzl.swidnik.pl. You may view this referenced service information at the FAA, Office of the Regional Counsel, Southwest Region, 10101 Hillwood Pkwy., Room 6N- 321, Fort Worth, TX 76177. For information on the availability of this material at the FAA, call (817) 222-5110. \n\t(3) The subject of this AD is addressed in European Union Aviation Safety Agency (EASA) AD 2020-0017, dated January 30, 2020. You may view the EASA AD on the internet at https://www.regulations.gov by searching for and locating it in Docket No. FAA-2021-0299. \n\n(j) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You mustuse this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Goodrich Actuation Systems Alert Service Bulletin 76378-500- 25-P01, Revision 0, dated December 3, 2019 (ASB 76378-500-25-P01). \n\n\n\n((Page 21920)) \n\n\n\n\n\tNote 1 to paragraph (j)(2)(i): ASB 76378-500-25-P01 is attached to WYTWORNIA SPRZETU KOMUNIKACYJNEGO ''PZL- Swidnik'' Spolka Akcyjna Alert Service Bulletin No. ASB-37-19-309, dated January 28, 2020, which is not incorporated by reference in this AD. \n\n\n\t(ii) (Reserved) \n\t(3) As the design approval holder for the product identified in paragraph (c) of this AD, contact PZL Swidnik S.A. for the Goodrich Actuation Systems service information identified in this AD, at WSK ''PZL-Swidnik'' S.A., Al. Lotnikow Polskich 1, 21-045 Swidnik, Poland; telephone +48-664 424 798; fax (+48) 817 225 710; or at www.pzl.swidnik.pl. \n\t(4) You may view this service information at the FAA, Office of the Regional Counsel, Southwest Region, 10101 Hillwood Pkwy., Room 6N-321, Fort Worth, TX 76177. For information on the availability of this material at the FAA, call 817-222-5110. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email fedreg.legal@nara.gov, or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. \n\n\n\tIssued on April 7, 2021. Lance T. Gant, Director, Compliance & Airworthiness Division, Aircraft Certification Service. (FR Doc. 2021-08567 Filed 4-23-21; 8:45 am) BILLING CODE 4910-13-P