Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2018-25-04 C Series Aircraft Limited Partnership (CSALP) (Type Certificate Previously Held by Bombardier, Inc.): Amendment 39- 19515; Docket No. FAA-2018-0799; Product Identifier 2018-NM-117-AD. \n\n((Page 63399)) \n\n(a) Effective Date \n\n\n\tThis AD is effective January 14, 2019. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to C Series Aircraft Limited Partnership (CSALP) (Type Certificate Previously Held by Bombardier, Inc.) airplanes, certificated in any category, identified in paragraphs (c)(1) and (c)(2) of this AD.(1) Model BD-500-1A10 airplanes, serial numbers 50001 and subsequent, equipped with blow-out panel part number D762213-503, D762216-505, or D762209-503. \n\t(2) Model BD-500-1A11 airplanes, serial numbers 55001 and subsequent, equipped with blow-out panel part number D762213-503, D762216-505, or D762209-503. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 50, Cargo and accessory compartment. \n\n(e) Reason \n\n\n\tThis AD was prompted by reports of dislodged cargo compartment blow-out panels. We are issuing this AD to address this condition, which could result in openings in the forward and aft cargo compartments. In the event of a cargo compartment fire, these unintended openings in the forward and aft cargo compartments would provide a path for smoke, fire, and Halon to enter the adjacent equipment bays, flight deck, and passenger cabin, which could delay smoke detection in the forward and aft cargo compartments and result in the forward and aft cargo compartments not being able to maintain the Halon concentration required for fire suppression. The cargo compartment fire may become uncontrollable if this condition is not addressed, which could result in the loss of controllability of the airplane. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Repetitive Inspections of the Forward and Aft Cargo Compartment Blow-Out Panels and Re-Installation \n\n\n\tWithin 7 days or 50 flight cycles, whichever occurs first, after the effective date of this AD, do a detailed inspection for any dislodged blow-out panel in the forward and aft cargo compartments, in accordance with C Series (Bombardier) Data Module BD500-A-J50-10- 01-01AAA-310B-A, ''Forward and aft cargo compartment blow-out panels--Visual check,'' Issue 002, dated May 16, 2018. Re-install all dislodged forward and aft cargo compartment blow-out panels before further flight, in accordance with C Series (Bombardier) Data Module BD500-A-J50-10-01-00AAA-521A-A, ''Decompression panels dislodging--Return to basic configuration,'' Issue 002, dated May 16, 2018. Thereafter, at intervals not to exceed 100 flight cycles, repeat the detailed inspection for any dislodged blow-out panel in the forward and aft cargo compartments. \n\n(h) Reporting \n\n\n\tIf any blow-out panel in the forward or aft cargo compartments is found dislodged during any inspection required by paragraph (g) of this AD, at the applicable time specified in paragraph (h)(1) or (h)(2) of this AD, report findings to the Bombardier customer response center (CRC) via email: crc_cseries@aero.bombardier.com. Reportable findings include the airplane serial number on which any dislodged blow-out panel was found, the date of inspection, and the part number and location of each dislodged blow-out panel. \n\t(1) If the inspection was done on or after the effective date of this AD: Submit the report within 30 days after the inspection. \n\t(2) If the inspection wasdone before the effective date of this AD: Submit the report within 30 days after the effective date of this AD. \n\n(i) Paperwork Reduction Act Burden Statement \n\n\n\tA federal agency may not conduct or sponsor, and a person is not required to respond to, nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a current valid OMB Control Number. The OMB Control Number for this information collection is 2120-0056. Public reporting for this collection of information is estimated to be approximately 1 hour per response, including the time for reviewing instructions, completing and reviewing the collection of information. All responses to this collection of information are mandatory. Comments concerning the accuracy of this burden and suggestions for reducing the burden should be directed to the FAA at: 800 Independence Ave. SW, Washington, DC 20591, Attn: Information Collection Clearance Officer, AES-200. \n\n(j) Other FAA AD Provisions \n\n\n\tThe following provisions also apply to this AD: \n\t(1) Alternative Methods of Compliance (AMOCs): The Manager, New York ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(2) Contacting the Manufacturer: For any requirement in this AD to obtain corrective actions from a manufacturer, the action must be accomplished using a method approved by the Manager, New York ACO Branch, FAA; or Transport Canada Civil Aviation (TCCA); or C Series Aircraft Limited Partnership's (CSALP's) TCCA Design Approval Organization (DAO). If approved by the DAO, the approval must include the DAO-authorized signature. \n\n(k) Related Information \n\n\n\t(1) Refer to Mandatory Continuing Airworthiness Information (MCAI) Canadian AD CF-2018-15, dated June 6, 2018, for related information. This MCAI may be found in the AD docket on the internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2018-0799. \n\t(2) For more information about this AD, contact Darren Gassetto, Aerospace Engineer, Mechanical Systems and Admin Services Section, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7323; fax 516 794 5531; email 9-avs-nyaco-cos@faa.gov. \n\n(l) MaterialIncorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise. \n\t(i) C Series (Bombardier) Data Module BD500-A-J50-10-01-00AAA- 521A-A, ''Decompression panels dislodging--Return to basic configuration,'' Issue 002, dated May 16, 2018. \n\t(ii) C Series (Bombardier) Data Module BD500-A-J50-10-01-01AAA- 310B-A, ''Forward and aft cargo compartment blow-out panels--Visual check,'' Issue 002, dated May 16, 2018. \n\t(3) For service information identified in this AD, contact Bombardier, Inc., 400 C(ocirc)te Vertu Road West, Dorval, Qu(eacute)bec H4S 1Y9, Canada; telephone 514-855-5000; fax 514-855- 7401; email thd.crj@aero.bombardier.com; internet http://www.bombardier.com. \n\t(4) You may view this service information at the FAA, Transport Standards Branch, 2200 South 216th St., Des Moines, WA. For information on the availability of this material at the FAA, call 206-231-3195. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.