Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2017-04-13 The Boeing Company: Amendment 39-18808; Docket No. \n\n((Page 11797)) \n\nFAA-2016-9053; Directorate Identifier 2016-NM-075-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective April 3, 2017. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to all The Boeing Company Model 747-8 and 747-8F series airplanes, certificated in any category. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 54, Nacelles/ pylons. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of damaged vapor seals,block seals, and heat shield seals on the outboard pylons between the engine strut and aft fairing. We are issuing this AD to detect and correct heat damage to the vapor seals between the engine strut and aft fairing. Such damage could allow flammable fluid leakage out of the aft fairing, which could result in an uncontrolled fire in the engine strut. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Repetitive Inspections \n\n\n\tAt the later of the times specified in paragraphs (g)(1) and (g)(2) of this AD: Do a detailed inspection for heat damage of the vapor seals on the outboard pylons between the strut and aft fairing of the numbers 1 and 4 engines, in accordance with Part 2 of the Accomplishment Instructions of Boeing Alert Service Bulletin 747- 54A2246, dated February 5, 2016. Repeat the inspection thereafter at intervals not to exceed 1,200 flight cycles. \n\t(1) Before the accumulation of 1,800 total flight cycles, or within 1,800 flight cycles after the most recent vapor seal, block seal, and heat shield seal replacement, whichever is later. \n\t(2) Within 6 months after the effective date of this AD. \n\n(h) Replacement \n\n\n\tIf during any inspection required by paragraph (g) of this AD any heat damage of any vapor seal is found: Before further flight, replace the vapor seal, heat shield seal, and block seal with new seals, in accordance with Part 3 of the Accomplishment Instructions of Boeing Alert Service Bulletin 747-54A2246, dated February 5, 2016. Repeat the inspection required by paragraph (g) of this AD within 1,800 flight cycles after doing the replacement, and thereafter at intervals not to exceed 1,200 flight cycles. \n\n(i) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (j) of this AD. Information may be emailed to: 9-ANM-Seattle-ACO-AMOC-Requests@faa.gov. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair, modification, or alteration required by this AD if it is approved by the Boeing Commercial Airplanes Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO, to make those findings. To be approved, the repair method, modification deviation, or alteration deviation must meet the certification basis of the airplane, and the approval must specificallyrefer to this AD. \n\t(4) For service information that contains steps that are labeled as Required for Compliance (RC), the provisions of paragraphs (i)(4)(i) and (i)(4)(ii) apply. \n\t(i) The steps labeled as RC, including substeps under an RC step and any figures identified in an RC step, must be done to comply with the AD. An AMOC is required for any deviations to RC steps, including substeps and identified figures. \n\t(ii) Steps not labeled as RC may be deviated from using accepted methods in accordance with the operator's maintenance or inspection program without obtaining approval of an AMOC, provided the RC steps, including substeps and identified figures, can still be done as specified, and the airplane can be put back in an airworthy condition. \n\n(j) Related Information \n\n\n\tFor more information about this AD, contact Tung Tran, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle ACO, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6505; fax: 425- 917-6590; email: tung.tran@faa.gov. \n\n(k) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Alert Service Bulletin 747-54A2246, dated February 5, 2016. \n\t(ii) Reserved. \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Contractual & Data Services (C&DS), 2600 Westminster Blvd., MC 110-SK57, Seal Beach, CA 90740; telephone 562-797-1717; Internet https://www.myboeingfleet.com. \n\t(4) You may view this service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.