Adoption of the Amendment
Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0 1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD):
2016-10-15 Fokker Services B.V.: Amendment 39-18526. Docket No. FAA-2015-5810; Directorate Identifier 2014-NM-116-AD.
(a) Effective Date
This AD becomes effective July 12, 2016.
(b) Affected ADs
None.
(c) Applicability
This AD applies to Fokker Services B.V. Model F.28 Mark 0070 and 0100 airplanes, certificated in any category, equipped with a center wing tank.
(d) Subject
Air Transport Association (ATA) of America Code 28, Fuel.
(e) Reason
This AD was prompted by a design review which revealed thata wiring failure, external to the center wing fuel tank, could cause a hot short circuit to a maximum level sensor wire, and result in excessive heating of the maximum level sensor element. We are issuing this AD to prevent the potential of ignition sources inside fuel tanks, which, in combination with flammable fuel vapors, could result in fuel tank explosions and consequent loss of the airplane.
(f) Compliance
Comply with this AD within the compliance times specified, unless already done.
(g) Wiring Modification
Within 24 months after the effective date of this AD: Modify the wiring of the maximum level sensors of the center wing fuel tank, as specified in paragraph (g)(1) or (g)(2) of this AD, as applicable. Before further flight after accomplishing the modification, do all applicable tests and corrective actions, in accordance with Part 5 of the Accomplishment Instructions of the service information identified in paragraph (j) of this AD.
(1) For post-SBF100-28-073 configuration airplanes: Do the modification in accordance with Part 1 or Part 3, as applicable, of the Accomplishment Instructions of the service information identified in paragraph (j) of this AD.
(2) For pre-SBF100-28-073 configuration airplanes: Do the modification in accordance with Part 2 or Part 4, as applicable, of the Accomplishment Instructions of the service information identified in paragraph (j) of this AD.
(h) Revise the Maintenance or Inspection Program
Within 30 days after installing the modification specified in paragraph (g)(1) or (g)(2) of this AD, as applicable: Revise the airplane maintenance or inspection program, as applicable, to incorporate the fuel airworthiness limitation items and critical design configuration control limitations (CDCCLs) specified in paragraph 2.L.(1)(c) of Fokker Service Bulletin SBF100-28-078, dated January 23, 2014.
(i) No Alternative Actions, Intervals, and/or CDCCLs
After accomplishing the revision required by paragraph (h) of this AD, no alternative actions (e.g., inspections), intervals, or CDCCLs may be used unless the actions, intervals, or CDCCLs are approved as an alternative method of compliance in accordance with the procedures specified in paragraph (k)(1) of this AD.
(j) Required Service Information
Do the actions specified in this AD in accordance with Fokker Service Bulletin SBF100-28-078, dated January 23, 2014, and Fokker Manual Change Notification MCNM-F100-166, dated January 23, 2014, as applicable.
(k) Other FAA AD Provisions
The following provisions also apply to this AD:
(1) Alternative Methods of Compliance (AMOCs): The Manager, International Branch, ANM-116, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly tothe International Branch, send it to ATTN: Tom Rodriguez, Aerospace Engineer, International Branch, ANM-116, Transport Airplane Directorate, FAA, 1601 Lind Avenue SW., Renton, WA 98057-3356; telephone 425-227-1137; fax 425-227-1149. Information may be emailed to: 9-ANM-116-AMOC-REQUESTS@faa.gov. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/ certificate holding district office.
(2) Contacting the Manufacturer: As of the effective date of this AD, for any requirement in this AD to obtain corrective actions from a manufacturer, the action must be accomplished using a method approved by the Manager, International Branch, ANM-116, Transport Airplane Directorate, FAA; or the European Aviation Safety Agency (EASA); or Fokker B.V. Service's EASA Design Organization Approval (DOA). If approved by the DOA, the approval must include the DOA- authorized signature.
(l)Related Information
Refer to Mandatory Continuing Airworthiness Information (MCAI) EASA Airworthiness Directive 2014-0138, dated May 30, 2014, for related information. This MCAI may be found in the AD docket on the Internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2015-5810.
(m) Material Incorporated by Reference
(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
(2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise.
(i) Fokker Service Bulletin SBF100-28-078, dated January 23, 2014, including the attached required drawings specified in paragraphs (m)(2)(i)(A), (m)(2)(i)(B), and (m)(2)(i)(C) of this AD, as applicable.
(A) Drawing W41192, Sheet 052, Issue AW, ``Retro-Fit Wiring Diagram, Tank Fueling/Defueling, Center Tank,'' undated;
(B) Drawing W41192, Sheet 054, Issue AW, ``Retro-Fit Wiring Diagram, Tank Fueling/Defueling,'' undated; and
(C) Drawing W59520-405, ``Cableloom Connection List,'' Sheet 3, Issue F, dated May 12, 2011.
(ii) Fokker Manual Change Notification MCNM-F100-166, dated January 23, 2014.
(3) For service information identified in this AD, contact Fokker Services B.V., Technical Services Dept., P.O. Box 1357, 2130 EL Hoofddorp, the Netherlands; telephone +31 (0)88-6280-350; fax +31 (0)88-6280-111; email technicalservices@fokker.com; Internet http://www.myfokkerfleet.com.
[[Page 36443]]
(4) You may view this service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221.
(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.