Adoption of the Amendment
Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows:
PART 39--AIRWORTHINESS DIRECTIVES
0 1. The authority citation for part 39 continues to read as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701.
Sec. 39.13 [Amended]
0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD):
2016-08-06 Airbus: Amendment 39-18482; Docket No. FAA-2015-4204; Directorate Identifier 2015-NM-001-AD.
(a) Effective Date
This AD becomes effective May 18, 2016.
(b) Affected ADs
None.
(c) Applicability
This AD applies to the Airbus airplanes specified in paragraphs (c)(1), (c)(2), (c)(3), and (c)(4) of this AD; certificated in any category; modified by Simmonds Precision Products, Inc., Supplemental Type Certificate (STC) ST00092BO (http://rgl.faa.gov/Regulatory_and_Guidance_Library/rgstc.nsf/0/D41C5AE8E46B4901862574900069E004?OpenDocument&Highlight=st00092bo).
(1) Model A300 B4-601, B4-603, B4-620, and B4-622 airplanes.
(2) Model A300 B4-605R and B4-622R airplanes.
(3) Model A300 F4-605R and F4-622R airplanes.
(4) Model A300 C4-605R Variant F airplanes.
(d) Subject
Air Transport Association (ATA) of America Code 28, Fuel.
(e) Reason
This AD was prompted by a report of chafing found on the overflow sensor harness of the surge tank, and subsequent contact between the electrical wiring and fuel tank structure. We are issuing this AD to prevent chafing of the harness and subsequent contact between the electrical wiring and fuel tank structure, which could result in electrical arcing and a fuel tank explosion.
(f) Compliance
Comply with this AD within the compliance times specified, unless already done.
(g) One-Time Inspection and Repair
Within 12 months after the effective date of this AD: Do the actions required by paragraphs (g)(1), (g)(2), and (g)(3) of this AD, in accordance with the Accomplishment Instructions of UTC Aerospace Systems Service Bulletin 300723-28-03 (V-1577), Revision 01, dated July 20, 2015.
(1) Perform a one-time general visual inspection for damage of the outer tank sensor harness, and if any damage is found on the expando sleeving, before further flight, do a detailed inspection of the underlying wires for exposed conductor wires. If any exposed conductor wire is found, before further flight, replace the outer wing harness assembly.
(2) Install new brackets and re-route the surge tank overflow sensor harness.
(3) Modify the harness protection.
(h) Credit for Previous Actions
This paragraph provides credit for actions required by paragraph (g) of this AD, if those actions were performed before the effective date of this AD using UTC Aerospace Systems Service Bulletin 300723- 28-03 (V-1577), dated October 10, 2014. This service information is not incorporated by reference in this AD.
(i) Alternative Methods of Compliance (AMOCs)
(1) The Manager, Boston Aircraft Certification Office (ACO), ANE-150, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (j)(1) of this AD.
(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office.
(j) Related Information
(1) For more information about this AD, contact Marc Ronell, Aerospace Engineer, Boston Aircraft Certification Office, ANE-150, FAA, 1200 District Avenue, Burlington, MA 01803; phone: 781-238- 7776; fax: 781-238-7170; email: marc.ronell@faa.gov.
(2) Service information identified in this AD that is not incorporated by reference is available at the addresses specified in paragraphs (k)(3) and (k)(4) of this AD.
(k) Material Incorporated by Reference
(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51.
[[Page 21735]]
(2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise.
(i) UTC Aerospace Systems Service Bulletin 300723-28-03 (V- 1577), Revision 01, dated July 20, 2015.
(ii) Reserved.
(3) For service information identified in this AD, contact Simmonds Precision Products, Inc., A UTC Aerospace Company, 100 Panton Road, Vergennes, VT 05491; phone 802-877-2911; fax 802-877- 4444; Internet http://www.utcaerospacesystems.com.
(4) You may view this service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221.
(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.