Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2015-07-07 The Boeing Company: Amendment 39-18135; Docket No. FAA- 2014-0920; Directorate Identifier 2014-NM-192-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective May 19, 2015. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to The Boeing Company Model 777-200, -200LR, - 300ER, and 777F series airplanes, certificated in any category, as identified in Boeing Special Attention Service Bulletin 777-28-0083, Revision 1, dated March 6, 2015. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 28: Fuel. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by a report of a jettison fuel pump that was shut off by the automatic shutoff system during the center tank fuel scavenge process on a short-range flight. We are issuing this AD to prevent extended dry running of the jettison fuel pumps, which can be a potential ignition source inside the main fuel tanks, and consequent fuel tank fire or explosion in the event that the jettison pump overheats or has an electrical fault. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Wiring and Software Changes \n\n\n\t(1) For Groups 1 through 4 airplanes, as identified in Boeing Special Attention Service Bulletin 777-28-0083, Revision 1, dated March 6, 2015: Within 36 months after the effective date of this AD, make wiring changes, modify power panels P110 and P210, install electrical load management system 2 (ELMS2) software, and accomplish the functional test and all applicable corrective actions, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-28-0083, Revision 1, dated March 6, 2015. Do all applicable corrective actions before further flight. \n\t(2) For Group 5 airplanes, as identified in Boeing Special Attention Service Bulletin 777-28-0083, Revision 1, dated March 6, 2015: Within 12 months after the effective date of this AD, install ELMS2 software, and accomplish the functional test and all applicable corrective actions, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-28- 0083, Revision 1, dated March 6, 2015. Do all applicable corrective actions before further flight. \n\n\n\n((Page 19881)) \n\n\n\n\n\tNote 1 to paragraph (g) of this AD: GE Aviation Service Bulletin 5000ELM-28-075, Revision 1, dated August 5, 2014; and GE Aviation Service Bulletin 6000ELM-28-076, Revision 1, dated August 5, 2014; are additional sources of guidance for modifying the P110 and P210 panels, respectively. \n\n(h) Credit for Previous Actions \n\n\n\tThis paragraph provides credit for actions required by paragraphs (g)(1) and (g)(2) of this AD, if those actions were performed before the effective date of this AD using Boeing Special Attention Service Bulletin 777-28-0083, dated September 8, 2014, which is not incorporated by reference in this AD. \n\n(i) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (j)(l) of this AD. Information may be emailed to: 9-ANM-Seattle-ACO-AMOC-Requests@faa.gov. \n\t(2) Before using any approved AMOC, notify yourappropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair required by this AD if it is approved by the Boeing Commercial Airplanes Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO, to make those findings. For a repair method to be approved, the repair must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\t(4) If the service information contains steps or procedures that are identified as RC (Required for Compliance), those steps or procedures must be done to comply with this AD; any steps or procedures that are not identified as RC are recommended. Those steps or procedures that are not identified as RC may be deviated from, done as part of other actions, or done using accepted methods different fromthose identified in the specified service information without obtaining approval of an AMOC, provided the steps or procedures identified as RC can be done and the airplane can be put back in a serviceable condition. Any substitutions or changes to steps or procedures identified as RC require approval of an AMOC. \n\n(j) Related Information \n\n\n\t(1) For more information about this AD, contact Tak Kobayashi, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6499; fax: 425-917-6590; email: takahisa.kobayashi@faa.gov. \n\t(2) For GE Aviation service information identified in this AD that is not incorporated by reference in this AD, contact GE Aviation service information identified in this AD, contact GE Aviation Fleet Support, 1 Neumann Way, Cincinnati, OH 45215; phone: 513-552-3272; email: aviation.fleetsupport@ge.com; Internet: http://www.geaviation.com. \n\n(k) Material Incorporatedby Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Special Attention Service Bulletin 777-28-0083, Revision 1, dated March 6, 2015. \n\t(ii) Reserved. \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544- 5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. \n\t(4) You may view this service information at FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.