2006-17-14 Bombardier, Inc. (Formerly Canadair): Docket No. FAA- 2006-25657; Directorate Identifier 2006-NM-187-AD; Amendment 39- 14735.
Effective Date
(a) This AD becomes effective September 7, 2006.
Affected ADs
(b) This AD supersedes AD 2006-16-07.
Applicability
(c) This AD applies to Bombardier Model CL-600-2B19 (Regional Jet Series 100 & 440) airplanes, certificated in any category, serial numbers 7003 through 7990 inclusive and 8000 and subsequent.
Unsafe Condition
(d) This AD results from incidents of short circuit failures of certain alternating current (AC) contactors located in the avionics bay. We are issuing this AD to prevent short circuit failures of certain AC contactors, which could result in arcing and consequent smoke or fire.
Compliance
(e) You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done.
Inspection and Corrective Action
(f) Within 800 flight hours or four months after the effective date of this AD, whichever occurs first: Do a general visual inspection of AC service bus contactors 1K4XD and 2K4XD, part number (P/N) D-18ZZA, and the utility bus contactor K4XA, P/N D-7GRZ, to determine which contactors have an Ultem 2200 terminal base plate (i.e., the plate is made from a black molded thermal plastic material), and apply RTV sealant to the terminal base plate, as applicable, by doing all the actions specified in the Accomplishment Instructions of Bombardier Service Bulletin 601R-24-122, Revision A, dated July 13, 2006. Do all applicable applications of sealant before further flight.
Note 1: For the purposes of this AD, a general visual inspection is: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. Amirror may be necessary to ensure visual access to all surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked."
Previous Actions Accomplished According to Other Service Information
(g) Actions accomplished before the effective date of this AD in accordance with Bombardier Drawing Number K601R50180, dated June 2, 2006; or Bombardier Service Bulletin 601R-24-122, dated June 27, 2006; are considered acceptable for compliance with the actions specified in paragraph (f) of this AD.
Parts Installation
(h) As of the effective date of this AD, no person may install AC contactor 1K4XD, 2K4XD, or K4XA, having an Ultem 2200 terminal base plate, on any airplane, unless RTV sealant has been applied to the terminalbase plate in accordance with Bombardier Service Bulletin 601R-24-122, Revision A, dated July 13, 2006.
Alternative Methods of Compliance (AMOCs)
(i)(1) The Manager, New York Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19.
(2) Before using any AMOC approved in accordance with Sec. 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office.
(3) AMOCs approved previously in accordance with AD 2006-16-07, are approved as AMOCs for the corresponding provisions of this AD.
Related Information
(j) Canadian airworthiness directive CF-2006-17, dated July 11, 2006, also addresses the subject of this AD.
Material Incorporated by Reference
(k) You must use Bombardier Service Bulletin 601R-24-122, Revision A, dated July 13, 2006, to perform the actions that are required by this AD, unless the AD specifies otherwise. On August 9, 2006 (71 FR 45364, August 9, 2006), the Director of the Federal Register approved the incorporation by reference of this document. Contact Bombardier, Inc., Canadair, Aerospace Group, P.O. Box 6087, Station Centre-ville, Montreal, Quebec H3C 3G9, Canada, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Room PL-401, Nassif Building, Washington, DC; on the Internet at http://dms.dot.gov; or at the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html .