2006-02-03 Raytheon Aircraft Company: Amendment 39-14455. Docket No. FAA-2005-22749; Directorate Identifier 2005-NM-188-AD.
Effective Date
(a) This AD becomes effective February 24, 2006.
Affected ADs
(b) None.
Applicability
(c) This AD applies to Raytheon Model Hawker 800XP airplanes, certificated in any category, serial numbers 258541, 258556, and 258567 through 258713 inclusive.
Unsafe Condition
(d) This AD results from a report of the installation of an incorrect fuse on the over-temperature switch on panel ZK in the rear equipment bay during airplane maintenance. We are issuing this AD to prevent a short circuit in the fuse and consequent heat damage to associated wiring and surrounding equipment, which could result in smoke or fire on the airplane.
Compliance
(e) You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done.
Inspect and Replace if Necessary
(f) Within 50 flight hours or 30 days after the effective date of this AD, whichever is first: Do a general visual inspection to determine if a 20-amp fuse is installed on the hydraulic over- temperature switch on panel ZK in the rear equipment bay in accordance with the Accomplishment Instructions of Raytheon Service Bulletin SB 24-3724, dated May 2005. If a 20-amp fuse is installed, before further flight, replace it with a 3-amp fuse in accordance with the Accomplishment Instructions of the service bulletin.
Note 1: For the purposes of this AD, a general visual inspection is: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked."
Note 2: A note in the Accomplishment Instructions of the Raytheon service bulletin instructs operators to contact Raytheon if any difficulty is encountered in accomplishing the service bulletin. However, any deviation from the instructions provided in the service bulletin must be approved as an alternative method of compliance (AMOC) under paragraph (g) of this AD.
Repair Approval
(g) Where the Raytheon Service Bulletin SB 24-3724, dated May 2005, says to contact the manufacturer if any sign of damage is found on associated terminals and wires: Before further flight, contact the Manager, Wichita Aircraft Certification Office, FAA, for applicable repair actions; then, before further flight, accomplish the applicable repair actions specified, according to a method approved by the Manager, Wichita Aircraft Certification Office.
Alternative Methods of Compliance (AMOCs)
(h)(1) The Manager, Wichita Aircraft Certification Office, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19.
(2) Before using any AMOC approved in accordance with Sec. 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office.
Material Incorporated by Reference
(i) You must use Raytheon Service Bulletin SB 24-3724, dated May 2005, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas, 67201-0085, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., room PL-401, Nassif Building, Washington, DC; on the Internet at http://dms.dot.gov; or at the National Archives and Records Administration (NARA). For information on the availability of this material at the NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html .