2004-11-09 Fokker Services B.V.: Amendment 39-13655. Docket 2002-NM-251-AD.
Applicability: Model F.28 Mark 0070 series airplanes, serial numbers 11521, and 11528 through 11585 inclusive; certificated in any category.
Compliance: Required as indicated, unless accomplished previously.
To prevent a short circuit in the electrical power center (EPC), possibly leading to a fire in the main cabin and damage to the airplane, or injury to passengers and flightcrew, accomplish the following:
Inspection, and Reinstallation if Necessary
(a) Within 6 months after the effective date of this AD, perform a general visual inspection of the 4 contactors having part number 9124-9283 located in the EPC for proper installation of the wires; in accordance with the Accomplishment Instructions of Fokker Service Bulletin SBF100-24-035, dated May 27, 2002.
(1) If the installation is correct, no further action is required by this AD.
(2) If the installation is incorrect, prior to further flight, reinstall the wires in accordance with the Accomplishment Instructions of the service bulletin.
Note 1: For the purposes of this AD, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked."
Exception to Service Bulletin Reporting
(b) Although Fokker Service Bulletin SBF100-24-035, dated May 27, 2002, specifies that all inspection results be reported to Fokker Services B.V., this AD does not include such a requirement.
Alternative Methods of Compliance
(c) In accordance with 14 CFR 39.19, the Manager, International Branch, ANM-116, FAA, Transport Airplane Directorate, is authorized to approve alternative methods of compliance for this AD.
Incorporation by Reference
(d) The actions shall be done in accordance with Fokker Service Bulletin SBF100-24-035, dated May 27, 2002. This incorporation by reference is approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Fokker Services B.V., P.O. Box 231, 2150 AE Nieuw-Vennep, the Netherlands. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.
Note 2: The subject of this AD is addressed in Dutch airworthiness directive 2002-112, dated July 31, 2002.
Effective Date
(e) This amendment becomes effective on July 9, 2004.