2009-26-09 General Electric Company: Amendment 39-16144. Docket No. FAA-2007-27687; Directorate Identifier 2000-NE-42-AD.
Effective Date
(a) This airworthiness directive (AD) becomes effective February 11, 2010.
Affected ADs
(b) This AD supersedes AD 2007-05-16, Amendment 39-14977 and AD 2007-07-07R1, Amendment 39-15179.
Applicability
(c) This AD applies to General Electric Company (GE) CF34-1A, - 3A, -3A1, -3A2, -3B, and -3B1 turbofan engines, with fan disks part numbers (P/Ns) 5921T18G01, 5921T18G09, 5921T18G10, 5921T54G01, 5922T01G02, 5922T01G04, 5922T01G05, 6020T62G04, 6020T62G05, 6078T00G01, 6078T57G01, 6078T57G02, 6078T57G03, 6078T57G04, 6078T57G05, and 6078T57G06 installed. These engines are installed on, but not limited to, Bombardier Canadair airplane models CL-600- 2A12, -2B16, and -2B19.
Unsafe Condition
(d) This AD results from an updated risk analysis by GE that shows we need to take corrective action that is more stringent. We are issuing this AD to prevent an uncontained failure of the fan disk, which could result in damage to the airplane.
Compliance
(e) You are responsible for having the actions required by this AD performed within the compliance times specified unless the actions have already been done.
Removing Certain Fan Disks From Service
(f) For fan disks listed by P/N and serial number (SN) in Table 2 of GE Alert Service Bulletin (ASB) CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008; or in Table 2 of GE ASB CF34-AL S/B 72- A0233, Revision 04, dated October 27, 2008, that have 8,000 CSN or more on the effective date of this AD, remove fan disks from service.
(g) For fan disks listed by P/N and serial number (SN) in Table 2 of GE Alert Service Bulletin (ASB) CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008; or in Table 2 of GE ASB CF34-AL S/B 72- A0233, Revision 04, dated October 27, 2008, that have fewer than 8,000 CSN on the effective date of this AD, remove fan disksfrom service before accumulating 8,000 CSN.
Inspections of Tier 1 Fan Disks
(h) For CF34-3A1 engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 22,000 CSN, and CF34-3B1 turbofan engines with Tier 1 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, do the following:
Tactile and Enhanced Visual (TEV) Inspections, Fluorescent Penetrant Inspections (FPI), and Eddy Current Inspections (ECI)
(1) For Tier 1 fan disks not already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) Perform a TEV inspection, an FPI, and an ECI on the Tier 1 fan disks within 650 cycles-in-service (CIS) after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructionsof GE ASB CF34-AL S/B 72-A0253, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(ii) Thereafter, perform repetitive ECI on the Tier 1 fan disks within intervals of 3,000 cycles-since-last inspection (CSLI). Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0252, dated October 27, 2008, to perform the repetitive ECI.
(2) For Tier 1 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) For Tier 1 fan disks with 2,500 or more CSLI on the effective date of this AD, perform an ECI on the Tier 1 fan disks within 500 CIS after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72- A0252, dated October 27, 2008, to perform the ECI.
(ii) For Tier 1 fan disks with fewer than 2,500 CSLI on theeffective date of this AD, perform an ECI on the Tier 1 fan disks within 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0252, dated October 27, 2008, to perform the ECI.
(iii) Thereafter, perform repetitive ECI on the Tier 1 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0252, dated October 27, 2008, to perform the repetitive ECI.
Inspections of Tier 2 Fan Disks
(i) For CF34-3A1 engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 22,000 CSN, and CF34-3B1 turbofan engines with Tier 2 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, do the following:
TEV Inspections, FPI, and ECI
(1) For Tier 2 fan disks not already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) Perform a TEV inspection, an FPI, and an ECI on the Tier 2 fan disks within 2,000 CIS after the effective date of this AD, or within 5,000 CIS after September 12, 2007, or by March 19, 2012, whichever occurs first. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0253, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(ii) Thereafter, perform repetitive eddy current inspections on the Tier 2 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72- A0252, dated October 27, 2008, to perform the repetitive ECI.
(2) For Tier 2 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) For Tier 2 fan disks with 2,500 or more CSLI on the effective date of this AD, perform an ECI on the Tier 2 fan disks within 500 CIS after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72- A0252, dated October 27, 2008, to perform the ECI.
(ii) For Tier 2 fan disks with fewer than 2,500 CSLI on the effective date of this AD, perform an ECI on the Tier 2 fan disks within 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0252, dated October 27, 2008, to perform the ECI.
(iii) Thereafter, perform repetitive ECI on the Tier 2 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0252, dated October 27, 2008, to perform the repetitive ECI.
Inspections of Tier 3 Fan Disks
(j) For CF34-3A1 engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 22,000 CSN, and CF34-3B1 turbofan engines with Tier 3 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, do the following:
TEV Inspections, FPI, and ECI
(1) For Tier 3 fan disks not already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, dated June 27, 2007, or earlier issue, perform a TEV inspection, an FPI, and an ECI on the Tier 3 fan disks within 5,000 CIS after September 12, 2007, or by March 19, 2012, whichever is earlier. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0253, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(2) For Tier 3 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-AL S/B 72-A0233, Revision 03, datedJune 27, 2007, or earlier issue, perform a TEV inspection and an ECI on the Tier 3 fan disks at the next shop visit. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72- A0233, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-AL S/B 72-A0253, dated October 27, 2008, to perform the TEV inspection and ECI.
(3) Repetitive ECI on the Tier 3 fan disks are not required.
Inspections of Tier 1 Fan Disks
(k) For CF34-3A1 turbofan engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 15,000 CSN, CF34-1A, CF34-3A, CF34-3A2, and CF34-3B turbofan engines with Tier 1 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, do the following:
TEV Inspections, FPI, and ECI
(1) For Tier 1 fan disks not already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue:
(i) Perform a TEV inspection, FPI, and ECI on the Tier 1 fan disks within 350 CIS after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72- A0234, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(ii) Thereafter, perform repetitive ECI on the Tier 1 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0235, dated October 27, 2008, to perform the repetitive ECI.
(2) For Tier 1 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) For Tier 1 fan disks with 2,500 or more CSLI on the effective date of this AD, perform an ECI on the Tier 1 fan disks within 500 CIS after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72- A0235, dated October 27, 2008, to perform the ECI.
(ii) For Tier 1 fan disks with fewer than 2,500 CSLI on the effective date of this AD, perform an ECI on the Tier 1 fan disks within 3,000 CSLI after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72- A0235, dated October 27, 2008, to perform the ECI.
(iii) Thereafter, perform repetitive ECI on the Tier 1 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0235, dated October 27, 2008, to perform the repetitive ECI.
Inspections of Tier 2 Fan Disks
(l) For CF34-3A1 turbofan engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 15,000 CSN, CF34-1A, CF34-3A, CF34-3A2, and CF34-3B turbofan engines with Tier 2 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, do the following:
TEV Inspections, FPI, and ECI
(1) For Tier 2 fan disks not already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) Perform a TEV inspection, FPI, and ECI on the Tier 2 fan disks within 2,000 CIS after the effective date of this AD, or within 3,500 CSN after September 12, 2007, or by March 19, 2012, whichever occurs first. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0234, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(ii) Thereafter, perform repetitive ECI on the Tier 2 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASBCF34-BJ S/B 72-A0235, dated October 27, 2008, to perform the repetitive ECI.
(2) For Tier 2 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue, do the following:
(i) For Tier 2 fan disks with 2,500 or more CSLI on the effective date of this AD, perform an ECI on the Tier 2 fan disks within 500 CIS after the effective date of this AD. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72- A0235, dated October 27, 2008, to perform the ECI.
(ii) For Tier 2 fan disks with fewer than 2,500 CSLI on the effective date of this AD, perform an ECI on the Tier 2 fan disks within 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0235, dated October 27, 2008, to perform the ECI.
(iii) Thereafter, perform repetitive ECI on the Tier 2 fan disks within intervals of 3,000 CSLI. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0235, dated October 27, 2008, to perform the repetitive ECI.
Inspections of Tier 3 Fan Disks
(m) For CF34-3A1 turbofan engines with fan drive shaft, P/N 6036T78P02, and airworthiness limitation section life limit of 15,000 CSN, CF34-1A, CF34-3A, CF34-3A2, and CF34-3B turbofan engines with Tier 3 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, do the following:
TEV Inspections, FPI, and ECI
(1) For Tier 3 fan disks not already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue, perform a TEV inspection, FPI, and ECI on the Tier 3 fan disks within 3,500 CIS after September 12, 2007, or by March 19, 2012, whichever is earlier. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0234, dated October 27, 2008, to perform the TEV inspection, FPI, and ECI.
(2) For Tier 3 fan disks, listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008; already inspected using GE ASB CF34-BJ S/B 72-A0212, Revision 03, dated June 27, 2007, or earlier issue, perform a TEV inspection and an ECI on the Tier 3 fan disks at the next shop visit. Use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0212, Revision 04, dated October 27, 2008, or use paragraph 3.A of the Accomplishment Instructions of GE ASB CF34-BJ S/B 72-A0234, dated October 27, 2008, to perform the TEV inspection and ECI.
(3) Repetitive ECI on the Tier 3 fan disks are not required.
Alternative Methods of Compliance
(n) The Manager, Engine Certification Office, has the authority to approve alternative methods of compliance for this AD if requested using the procedures found in 14 CFR 39.19.
Mandatory Terminating Action
(o) Remove from service, Tier 1 and Tier 2 fan disks listed by P/N, SN, and Tier in Table 1 of GE ASB CF34-AL S/B 72-A0233, Revision 04, dated October 27, 2008; or CF34-BJ S/B 72-0212, Revision 04, dated October 27, 2008, before they exceed their limited life cycles or September 30, 2018, whichever occurs first.
Related Information
(p) Contact Tara Chaidez, Aerospace Engineer, Engine Certification Office, FAA, Engine and Propeller Directorate, 12 New England Executive Park, Burlington, MA 01803; e-mail: tara.chaidez@faa.gov; telephone (781) 238-7773; fax (781) 238-7199, for more information about this AD.
Material Incorporated by Reference
(q) You must use the service information specified in the following Table 1 to perform the inspections required by this AD. The Director of the Federal Register approved the incorporation by reference of the documents listed in the following Table 1 in accordance with5 U.S.C. 552(a) and 1 CFR part 51. Contact General Electric Company via Lockheed Martin Technology Services, 10525 Chester Road, Suite C, Cincinnati, Ohio 45215; telephone (513) 672- 8400; fax (513) 672-8422, for a copy of this service information. You may review copies at the FAA, New England Region, 12 New England Executive Park, Burlington, MA; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http:// www.archives.gov/federal-register/cfr/ibr-locations.html.
Table 1--Incorporation by Reference
Service Bulletin No.
Page
Revision
Date
CF34-AL S/B 72-A0233
Total Pages 107
ALL
04
October 27, 2008
CF34-AL S/B 72-A0252
Total Pages 22
ALL
Original
October 27, 2008
CF34-AL S/B 72-A0253
Total Pages 77
ALL
Original
October 27, 2008
CF34-BJ S/B 72-A0212
Total Pages 111
ALL
04
October 27, 2008
CF34-BJ S/B 72-A0234
Total Pages 82
All
Original
October 27, 2008
CF34-BJ S/B 72-A0235
Total Pages 20
ALL
Original
October 27, 2008