2007-07-07R1 General Electric Company: Amendment 39-15179. Docket No. FAA-2007-27687; Directorate Identifier 2000-NE-42-AD.
Effective Date
(a) This airworthiness directive (AD) becomes effective September 12, 2007.
Affected ADs
(b) This AD revises AD 2007-07-07.
Applicability
(c) This AD applies to General Electric Company (GE) CF34-1A, - 3A, -3A1, -3A2, -3B, and -3B1 turbofan engines, with fan disks part numbers (P/Ns) 5921T18G01, 5921T18G09, 5921T18G10, 5921T54G01, 5922T01G02, 5922T01G04, 5922T01G05, 6020T62G04, 6020T62G05, 6078T00G01, 6078T57G01, 6078T57G02, 6078T57G03, 6078T57G04, 6078T57G05, and 6078T57G06 installed. These engines are installed on, but not limited to, Bombardier Canadair airplane models CL-600- 2A12, -2B16, and -2B19.
Unsafe Condition
(d) This AD results from a comment received on AD 2007-07-07, and from GE recently issuing revisions to the applicable GE Alert Service Bulletins (ASBs). We are issuing this AD to prevent an uncontained fan disk failure and airplane damage.
Compliance
(e) You are responsible for having the actions required by this AD performed within the compliance times specified unless the actions have already been done.
Removal of Certain Fan Disks From Service
(f) For fan disks listed by P/N and serial number (SN) in the following Table A that have fewer than 8,000 cycles-since-new (CSN) on the effective date of this AD, replace fan disks before accumulating 8,000 CSN:
Table A.--Fan Disks That Require Removal Based on Blended Callouts
Disk Part Number
Disk Serial Number
6078T57G02
GAT6306N
6078T00G01
GAT3860G
6078T57G02
GAT1924L
5922T01G04
GAT9599G
6078T57G04
GEE05831
6078T57G04
GEE06612
6078T57G04
GEE06618
6078T57G04
GEE06974
6078T57G04
GEE06980
6078T57G05
GEE143FY
6078T57G05
GEE1453G
6078T57G05
GEE14452
6078T57G05
GEE145NA
6078T57G04
GEE08086
6078T57G04
GEE09287
6078T57G04
GEE09337
6078T57G05
GEE12720
6078T57G05
GEE142146078T57G05
GEE142YT
6078T57G05
GEE146GT
(g) For fan disks listed in Table A of this AD that have 8,000 CSN or more on the effective date of this AD, replace the disk within 15 days after the effective date of this AD.
Inspections of Fan Disks Installed in Regional Jet Airplanes
(h) For CF34-3A1 and CF34-3B1 turbofan engines installed on Bombardier Canadair CL600-2B19 Regional Jet airplanes:
On-Wing Tactile and Enhanced Visual (TEV) Inspection
(1) On-wing TEV inspect the fan disks listed by P/N and SN in Table 1 of GE ASB No. CF34-AL S/B 72-A0231, Revision 1, dated June 27, 2007, using the compliance times specified in the following Table B:
Table B.--Regional Jet On-wing Fan Disk Inspection Compliance Times
For Fan Disks:
Inspect:
(i) That have not had a shop-level inspection.
Within 500 flight hours after the effective date of this AD.
(ii) That are marked with an asterisk in Table 1 of GE ASB No. CF34-AL S/B 72-A0231, Revision 1, dated June27, 2007.
Within 500 flight hours after the effective date of this AD.
(2) Use paragraphs 3.A. through 3.A.(13) of the Accomplishment Instructions of GE ASB No. CF34-AL S/B 72-A0231, Revision 1, dated June 27, 2007, to do the inspection.
Shop-Level Inspection
(3) Within 5,000 flight hours or 5 calendar years after the effective date of this AD, whichever occurs first, fluorescent penetrant inspect (FPI), TEV inspect, and eddy current inspect (ECI) at shop-level for cracks and electrical arc-out defects on the fan disks listed by P/N and SN in Table 1 of GE ASB No. CF34-AL S/B 72- A0233, Revision 3, dated June 27, 2007.
(4) Use paragraphs 3.A.(1) through 3.A.(6) of the Accomplishment Instructions of GE ASB No. CF34-AL S/B 72-A0233, Revision 3, dated June 27, 2007, to do the inspections.
Shop-Level Inspection Exemption
(5) Fan disks are exempt from the shop-level inspection, that meet the following criteria:
(i) Fan disks inspected before the effective date of this AD per GE Engine Manual No. SEI-756, Section 72-21-00 (FAN ROTOR ASSEMBLY INSPECTION); and
(ii) That have accumulated no more than 100 cycles since that inspection; and
(iii) That pass the on-wing TEV inspection in paragraph (h)(2) of this AD.
Inspection of Fan Disks Installed in Business Jet Airplanes
(i) For CF34-1A, -3A, -3A1, -3A2, and -3B turbofan engines installed on Bombardier Canadair Models CL-600-2A12 (CL-601), CL- 600-2B16 (CL-601-3A), (CL-601-3R), and (CL-604) Business Jet airplanes:
(1) FPI, TEV inspect, and ECI for cracks and electrical arc-out defects at shop-level on the fan disks listed by P/N and SN in Table 1 of GE ASB No. CF34-BJ S/B 72-A0212, Revision 3, dated June 27, 2007, using the compliance times specified in the following Table C:
Table C.--Business Jet Shop-level Fan Disk Inspection Compliance Times
For Fan Disks:
Inspect:
(i) That have not had a shop-level inspection and have more than 5,500 flight hours on the effective date of this AD.
Within 500 flight hours after the effective date of this AD.
(ii) That have not had a shop-level inspection and have 5,500 or fewer flight hours on the effective date of this AD.
Within accumulating a total of 6,000 fan disk operating hours-since-new.
(iii) That have had a shop-level inspection and have 5,500 or fewer flight hours on the effective date of this AD.
Within accumulating an additional 6,000 fan disk operating hours-since-shop-level inspection, or within 5 calendar years from the effective date of this AD, whichever occurs first.
(2) Use paragraphs 3.A. through 3.A.(10) of the Accomplishment Instructions of GE ASB No. CF34-BJ S/B 72-A0212, Revision 3, dated June 27, 2007, to do the inspections.
Reporting Requirements
(j) Under the provisions of the Paperwork Reduction Act of 1980 (44 U.S.C. 3501 et seq.), the Office of Management and Budget (OMB) has approved the information collection requirements contained in this AD, and has assigned OMB Control Number 2120-0056.
(1) Report the results of the on-wing inspections performed in paragraph (h)(2) of this AD by following the instructions in paragraph 3.A.(14) of the Accomplishment Instructions of GE ASB No. CF34-AL S/B 72-A0231, Revision 1, dated June 27, 2007.
(2) Report the results of the shop-level inspections performed in paragraph (h)(4) of this AD by following the instructions in paragraph 3.A.(3)(b)11 of the Accomplishment Instructions of GE ASB No. CF34-AL S/B 72-A0233, Revision 3, dated June 27, 2007.
(3) Report the results of the shop-level inspections performed in paragraph (i)(2) of this AD by following the instructions in paragraph 3.A.(3)(b)11 of the Accomplishment Instructions of GE ASB No. CF34-AL S/B 72-A0212, Revision 3, dated June 27, 2007.
Previous Credit
(k) Credit is allowed for:
(1) Fan disks previously shop-level inspected before the effective date of this AD using GE ASB No. CF34-AL S/B 72-A0233, dated March 7, 2007, Revision 1, dated March 16, 2007, or Revision 2, dated March 22, 2007; and GE ASB No. CF34-BJ S/B 72-A0212, dated March 7, 2007, Revision 1, dated March 16, 2007, or Revision 2, dated March 22, 2007.
(2) Fan disks previously on-wing TEV inspected before the effective date of this AD using GE ASB No. CF34-AL S/B 72-A0231, dated March 7, 2007.
Alternative Methods of Compliance
(l) The Manager, Engine Certification Office, has the authority to approve alternative methods of compliance for this AD if requested using the procedures found in 14 CFR 39.19.
Related Information
(m) Emergency AD 2007-04-51 and AD 2007-05-16 also pertain to the subject of this AD.
Material Incorporated by Reference
(n) You must use the General Electric Company Alert Service Bulletins listed in Table D of this AD to perform the inspections required by this AD. The Director of the Federal Register approved the incorporation by reference of the documents listed in Table D of this AD in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. You can get a copy from General Electric Company via Lockheed Martin Technology Services, 10525 Chester Road, Suite C, Cincinnati, Ohio 45215; telephone (513) 672-8400; fax (513) 672-8422. You can review copies at the FAA, New England Region, 12 New England Executive Park, Burlington, MA; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html .
Table D.--Incorporation by Reference
Alert Service Bulletin No.
Page Number
Revision
Date
CF34-AL S/B 72-A0231
Total Pages: 94
All
1
June 27, 2007
CF34-AL S/B 72-A0233
Total Pages: 92
All
3
June 27, 2007
CF34-BJ S/B 72-A0212
Total Pages: 96
All
3
June 27, 2007